Assessment Year | 2015 |
---|---|
Principal Product | Flatware |
NAICS | 339910: Jewelry and Silverware Manufacturing |
SIC | 3914: Silverware, Plated Ware, and Stainless Steel Ware |
Sales Range | $1 M to 5M |
# of Employees | 35 |
Plant Area |
240,000
ft2
|
Annual Production | 250,000
lb
|
Production Hrs. Annual | 2,184
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $125,510 | 3,159,730 |
kWh
|
$0.040 |
Electricity Demand | $47,222 | 10,892 |
kW-mo/yr
|
$4.34 |
Natural Gas | $29,738 | 5,003 |
MMBtu
|
$5.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,283 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $39,138 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 4.821: Pay bills on time to avoid late fees | $813 | - | - | - | - | - | $813 | |
02 | 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads | $738 | - |
$738
18,590
kWh
|
- | - | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $486 | - |
$315
7,925
kWh
|
$171
-
kW-mo/yr
|
- | - | - | |
04 | 2.8118: Check for accuracy of utility / power meters | $243 | - | - | - | - | - | $243 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,889 | $930 |
$181
4,555
kWh
|
$27
-
kW-mo/yr
|
- | $1,050 | $631 | |
06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $17,027 | $20,360 |
$14,673
369,600
kWh
|
$4,330
-
kW-mo/yr
|
$(-1,976.0)
-
MMBtu
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,544 | $1,250 |
$1,009
25,428
kWh
|
$535
-
kW-mo/yr
|
- | - | - | |
08 | 2.7232: Replace existing hvac unit with high efficiency model | $18,009 | $17,408 | - | - |
$18,009
-
MMBtu
|
- | - | |
09 | 3.1161: Eliminate/reduce an operation | $1,222 | $2,440 |
$(-6.0)
(-149)
kWh
|
$(-145.0)
-
kW-mo/yr
|
- | $450 | $923 | |
10 | 2.4221: Install compressor air intakes in coolest locations | $419 | - |
$274
6,906
kWh
|
$145
-
kW-mo/yr
|
- | - | - | |
11 | 2.6211: Conserve energy by efficient use of vending machines | $112 | $462 |
$112
2,828
kWh
|
- | - | - | - | |
12 | 2.7131: Add area lighting switches | $781 | $3,851 |
$355
8,954
kWh
|
$426
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $43,283 | $46,701 |
$17,651
444,637
kWh
|
$5,489
-
kW-mo/yr
|
$16,033
-
MMBtu
|
$1,500 | $2,610 | ||
TOTAL IMPLEMENTED | $39,138 | $38,698 |
$15,866
399,651
kWh
|
$4,502
-
kW-mo/yr
|
$16,033
-
MMBtu
|
$1,050 | $1,687 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs