| IC0325 #11 Y:2025 | 11 | 2025 | Eliminate leaks in inert gas and compressed air lines/ valves | $149 | $144 | |
| IC0325 #10 Y:2025 | 10 | 2025 | Eliminate or reduce compressed air usage | $1,175 | $2,940 | |
| IC0325 #09 Y:2025 | 09 | 2025 | Eliminate leaks in inert gas and compressed air lines/ valves | $1,137 | - | |
| IC0325 #08 Y:2025 | 08 | 2025 | Reduce the pressure of compressed air to the minimum required | $1,716 | - | |
| IC0325 #07 Y:2025 | 07 | 2025 | Use waste heat from hot flue gases to preheat incoming fluids | $2,149 | $5,256 | |
| IC0325 #06 Y:2025 | 06 | 2025 | Use adjustable frequency drive or multiple speed motors on existing system | $2,350 | $246 | |
| IC0325 #05 Y:2025 | 05 | 2025 | Use waste heat from flue gases to heat space conditioning air | $4,795 | $3,414 | |
| IC0325 #04 Y:2025 | 04 | 2025 | Use adjustable frequency drive or multiple speed motors on existing system | $7,318 | $7,240 | |
| IC0325 #03 Y:2025 | 03 | 2025 | Use adjustable frequency drive or multiple speed motors on existing system | $13,138 | $5,309 | |
| IC0325 #02 Y:2025 | 02 | 2025 | Install efficient rectifiers | $8,079 | $8,129 | |
| IC0325 #01 Y:2025 | 01 | 2025 | Use or replace with energy efficient substitutes | $34,094 | $58,119 | |
| BD0394 #07 Y:2011 | 07 | 2011 | Install occupancy sensors | $855 | $225 | |
| BD0394 #06 Y:2011 | 06 | 2011 | Install compressor air intakes in coolest locations | $1,201 | $400 | |
| BD0394 #05 Y:2011 | 05 | 2011 | Utilize higher efficiency lamps and/or ballasts | $2,201 | $1,652 | |
| BD0394 #04 Y:2011 | 04 | 2011 | Utilize higher efficiency lamps and/or ballasts | $3,571 | $2,360 | |
| BD0394 #03 Y:2011 | 03 | 2011 | Eliminate leaks in inert gas and compressed air lines/ valves | $6,544 | $2,400 | |
| BD0394 #02 Y:2011 | 02 | 2011 | Improve combustion control capability | $35,291 | $9,000 | |
| BD0394 #01 Y:2011 | 01 | 2011 | Improve combustion control capability | $58,796 | $139,000 | |
| IC0064 #05 Y:2003 | 05 | 2003 | Use adjustable frequency drive or multiple speed motors on existing system | $20,210 | $85,743 | |
| IC0064 #04 Y:2003 | 04 | 2003 | Utilize energy-efficient belts and other improved mechanisms | $2,718 | $8,856 |