39

matching recommendations
$
$
ARC 2+ Digits Required
NAICS 3+ Digits Required
SIC Secondary smelting and refining of nonferrous metals
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
IC0082 #02 Y:2004 Use waste heat from hot flue gases to preheat $212,513 $1,533
IC0082 #01 Y:2004 Replace heat treating oven with more efficient unit $158,811 -
BD0106 #08 Y:1997 Replace existing equipment with more suitable substitutes $154,560 $23,000
BD0106 #07 Y:1997 Contract a wood pallet recycling company $10,330 $210
BD0106 #06 Y:1997 Convert to high volume low pressure (hvlp) paint guns $85,424 $67,500
BD0106 #05 Y:1997 Install occupancy sensors $967 $650
BD0106 #04 Y:1997 Install compressor air intakes in coolest locations $1,022 $800
BD0106 #03 Y:1997 Use most efficient type of electric motors $1,941 $3,160
BD0106 #02 Y:1997 Make a practice of turning off lights when not needed $3,383 -
BD0106 #01 Y:1997 Install partitions to reduce size of conditioned space $14,857 $7,000
WI0234 #06 Y:1995 Convert to aqueous cleaning system $26,400 $18,000
WI0234 #05 Y:1995 Recharge batteries on during off-peak demand periods $863 -
WI0234 #04 Y:1995 Cover open tanks $1,743 $3,312
WI0234 #03 Y:1995 Insulate bare equipment $1,846 $1,187
WI0234 #02 Y:1995 Insulate bare equipment $3,351 $1,171
WI0234 #01 Y:1995 Install vinyl strip / high speed / air curtain doors $5,900 $22,275
WI0219 #03 Y:1994 Install occupancy sensors $744 $375
WI0219 #02 Y:1994 Utilize higher efficiency lamps and/or ballasts $644 $782
WI0219 #01 Y:1994 Reschedule plant operations or reduce load to avoid peaks $1,622 -