Assessment Year | 1998 |
---|---|
Principal Product | Fabricated Metal |
NAICS |
n/a
|
SIC | 3341: Secondary Smelting and Refining of Nonferrous Metals |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
130,000
ft2
|
Annual Production | 180,000
pieces
|
Production Hrs. Annual | 7,072
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $99,639 | 2,092,614 |
kWh
|
$0.048 |
Electricity Demand | $11,392 | 4,831 |
kW-mo/yr
|
$2.36 |
Electricity Fees | $5,830 | - |
|
- |
Natural Gas | $53,745 | 11,404 |
MMBtu
|
$4.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $272,484 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7496: Install partitions to reduce size of conditioned space | $14,857 | $7,000 | - | - |
$14,857
-
MMBtu
|
- | - | - | |
02 | 2.7124: Make a practice of turning off lights when not needed | $3,383 | - |
$3,121
65,651
kWh
|
$262
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $1,941 | $3,160 |
$1,826
38,394
kWh
|
$115
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,022 | $800 |
$938
19,637
kWh
|
$84
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7135: Install occupancy sensors | $967 | $650 |
$881
18,464
kWh
|
$86
-
kW-mo/yr
|
- | - | - | - | |
06 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $85,424 | $67,500 | - | - | - | - | - | $85,424 | |
07 | 3.5316: Contract a wood pallet recycling company | $10,330 | $210 | - | - | - | - | $10,330 | - | |
08 | 4.652: Replace existing equipment with more suitable substitutes | $154,560 | $23,000 | - | - | - | $154,560 | - | - | |
TOTAL RECOMMENDED | $272,484 | $102,320 |
$6,766
142,146
kWh
|
$547
-
kW-mo/yr
|
$14,857
-
MMBtu
|
$154,560 | $10,330 | $85,424 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs