18
matching recommendationsID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
---|---|---|---|---|---|---|
SF0380 #06 Y:2009 | 06 | 2009 | Install occupancy sensors | $217 | $631 | |
SF0380 #05 Y:2009 | 05 | 2009 | Use photocell controls | $2,873 | $7,164 | |
SF0380 #04 Y:2009 | 04 | 2009 | Utilize energy-efficient belts and other improved mechanisms | $156 | $272 | |
SF0380 #03 Y:2009 | 03 | 2009 | Utilize higher efficiency lamps and/or ballasts | $1,815 | $3,010 | |
SF0380 #02 Y:2009 | 02 | 2009 | Reduce the pressure of compressed air to the minimum required | $2,794 | $1,762 | |
SF0380 #01 Y:2009 | 01 | 2009 | Eliminate leaks in inert gas and compressed air lines/ valves | $2,300 | $360 | |
SF0297 #05 Y:2004 | 05 | 2004 | Reduce illumination to minimum necessary levels | $486 | $1,243 | |
SF0297 #04 Y:2004 | 04 | 2004 | Use insulation in furnaces to facilitate heating / cooling | $34,144 | $50,073 | |
SF0297 #03 Y:2004 | 03 | 2004 | Use most efficient type of electric motors | $558 | $553 | |
SF0297 #02 Y:2004 | 02 | 2004 | Utilize higher efficiency lamps and/or ballasts | $1,017 | $1,783 | |
SF0297 #01 Y:2004 | 01 | 2004 | Eliminate leaks in inert gas and compressed air lines/ valves | $1,571 | - | |
SF0119 #07 Y:1997 | 07 | 1997 | Cross-train personnel to avoid lost time | $779,640 | $275,000 | |
SF0119 #06 Y:1997 | 06 | 1997 | Increase amount of waste recovered for resale | $250 | $250 | |
SF0119 #05 Y:1997 | 05 | 1997 | Lease / purchase baler; sell cardboard to recycler | $1,872 | $250 | |
SF0119 #04 Y:1997 | 04 | 1997 | Replace electrically-operated equipment with fossil fuel equipment | $354 | $845 | |
SF0119 #03 Y:1997 | 03 | 1997 | Eliminate or reduce compressed air usage | $812 | $3,000 | |
SF0119 #02 Y:1997 | 02 | 1997 | Use most efficient type of electric motors | $871 | $514 | |
SF0119 #01 Y:1997 | 01 | 1997 | Utilize higher efficiency lamps and/or ballasts | $13,708 | $30,720 |