| Assessment Year | 2026 |
|---|---|
| Principal Product | Lumber products |
| NAICS | 321920: Wood Container and Pallet Manufacturing |
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $100 M to 500M |
| # of Employees | 200 |
| Plant Area |
1,300,000
ft2
|
| Annual Production | 100,000
units
|
| Production Hrs. Annual | 5,355
hrs
|
| Location (State) | California |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $442,212 | 3,833,147 |
kWh
|
$0.12 | |
| Electricity Demand | $552,317 | 12,217 |
kW-mo/yr
|
$45.21 | |
| Natural Gas | $64,281 | 3,276 |
MMBtu
|
$19.62 | |
| LPG | $67,604 | 3,493 |
MMBtu
|
$19.35 | |
| Fuel Oil #1 | $52,381 | 1,709 |
MMBtu
|
$30.65 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,453 | 497,000 |
Tgal
|
$0.003 | |
| Other Liquid (haz) | $2,485 | 529 |
gal
|
$4.70 | |
| Solid Waste (non-haz) | $61,402 | 1,764,000 |
lb
|
$0.035 | |
| TOTAL YEARLY COSTS | $1,244,135 | ||||
| RECOMMENDED SAVINGS* | $205,453 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $21,985 | $166,983 |
$14,390
108,492
kWh
|
$7,595
-
kW-mo/yr
|
- | |
| 02 | 2.4239: Eliminate or reduce compressed air usage | $1,611 | - |
$1,611
12,150
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,482 | - |
$3,482
26,250
kWh
|
- | - | |
| 04 | 2.9114: Use solar heat to make electricty | $156,271 | $1,409,408 |
$117,755
894,076
kWh
|
$38,516
-
kW-mo/yr
|
- | |
| 05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $21,424 | $57,800 |
$(-25.0)
(-190)
kWh
|
$(-3,391.0)
-
kW-mo/yr
|
$24,840 | |
| 06 | 2.4239: Eliminate or reduce compressed air usage | $680 | - |
$680
5,126
kWh
|
- | - | |
| TOTAL RECOMMENDED | $205,453 | $1,634,191 |
$137,893
1,045,904
kWh
|
$42,720
-
kW-mo/yr
|
$24,840 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs