Assessment Year 2026
Principal Product Filter Media
NAICS 321999: All Other Miscellaneous Wood Product Manufacturing
SIC 2499: Wood Products, Not Elsewhere Classified
Sales Range $100
M
to 500
M
# of Employees 150
Plant Area 540,000
ft2
Annual Production 45,519,527
lb
Production Hrs. Annual 8,400
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,453,663 15,283,258
kWh
Electricity Demand $382,408 28,932
kW-mo/yr
Electricity Fees $74,073 -
Natural Gas $2,132,197 415,539
MMBtu
Other Gas $13,965 1
MMBtu
TOTAL YEARLY COSTS $4,056,307
RECOMMENDED SAVINGS* $1,910,683 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
01 2.7224: Reduce space conditioning during non-working hours $8,247 $252 - - $8,247
-
MMBtu
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $23,318 $2,383 $23,318
245,542
kWh
- - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $2,244 $805 $1,560
16,416
kWh
$297
-
kW-mo/yr
- $388
04 2.2136: Install / repair insulation on steam lines $4,761 $3,286 - - $4,761
-
MMBtu
-
05 2.7135: Install occupancy sensors $1,925 $1,523 $1,925
20,261
kWh
- - -
06 2.2135: Repair and eliminate steam leaks $114,527 $100,000 - - $114,527
-
MMBtu
-
07 4.631: Install an uninteruptable power supply $1,428,571 $1,420,000 - - - $1,428,571
08 2.2414: Use waste heat from hot flue gases to preheat $322,534 $422,066 - - $322,534
-
MMBtu
-
09 2.4322: Use or replace with energy efficient substitutes $371 $548 $200
2,102
kWh
$38
-
kW-mo/yr
- $134
10 2.6211: Conserve energy by efficient use of vending machines $757 $1,715 $757
7,971
kWh
- - -
11 2.7232: Replace existing hvac unit with high efficiency model $3,426 $29,728 $1,078
11,347
kWh
- $2,348
-
MMBtu
-
TOTAL RECOMMENDED $1,910,683 $1,982,305 $28,837
303,640
kWh
$335
-
kW-mo/yr
$452,418
-
MMBtu
$1,429,093
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs