| Assessment Year | 1996 |
|---|---|
| Principal Product | Corrugated paperboard |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
155,600
ft2
|
| Annual Production | 360,000
thousand feet
|
| Production Hrs. Annual | 4,267
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $100,540 | 2,721,278 |
kWh
|
$0.037 |
| Electricity Demand | $53,467 | 8,007 |
kW-mo/yr
|
$6.68 |
| Electricity Fees | $6,872 | - |
|
- |
| Natural Gas | $150,580 | 29,970 |
MMBtu
|
$5.02 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,930 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,360 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $9,470 | $13,110 | - |
$9,470
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $170 | $240 |
$40
2,052
kWh
|
$130
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.2136: Install / repair insulation on steam lines | $1,000 | $1,000 | - | - |
$1,000
-
MMBtu
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,080 | $500 |
$1,080
53,927
kWh
|
- | - | - | - | |
| 05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $870 | - |
$220
11,137
kWh
|
$650
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.7134: Use photocell controls | $240 | $30 |
$80
4,103
kWh
|
$160
-
kW-mo/yr
|
- | - | - | |
| 07 | 3.4112: Recovery metals from rinse water(evap., ion exchange, ro, electrolysis, electrodialysis) and reuse rinse water | $20,000 | $975 | - | - | - |
$20,000
-
Tgal
|
- | |
| 08 | 3.4133: Clean fouling from water lines regularly | $100 | $100 | - | - | - | - |
$100
-
gal
|
|
| TOTAL RECOMMENDED | $32,930 | $15,955 |
$1,420
71,219
kWh
|
$10,410
-
kW-mo/yr
|
$1,000
-
MMBtu
|
$20,000
-
Tgal
|
$100
-
gal
|
||
| TOTAL IMPLEMENTED | $3,360 | $1,770 |
$1,420
71,219
kWh
|
$940
-
kW-mo/yr
|
$1,000
-
MMBtu
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs