16
matching recommendations| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| DS0101 #06 Y:1997 | 06 | 1997 | Use mechanical stripping methods | $675 | $2,295 | |
| DS0101 #05 Y:1997 | 05 | 1997 | Minimize water usage | $5,125 | $(-6,000.0) | |
| DS0101 #04 Y:1997 | 04 | 1997 | Minimize water usage | $2,739 | - | |
| DS0101 #03 Y:1997 | 03 | 1997 | Recover waste heat from equipment | $1,424 | $820 | |
| DS0101 #02 Y:1997 | 02 | 1997 | Install compressor air intakes in coolest locations | $1,905 | $1,750 | |
| DS0101 #01 Y:1997 | 01 | 1997 | Utilize higher efficiency lamps and/or ballasts | $2,339 | $10,895 | |
| DS0033 #10 Y:1995 | 10 | 1995 | Recover waste heat from equipment | $6,581 | $16,000 | |
| DS0033 #09 Y:1995 | 09 | 1995 | Change rate schedules or other changes in utility service | $30,890 | $268,600 | |
| DS0033 #08 Y:1995 | 08 | 1995 | Insulate bare equipment | $850 | $284 | |
| DS0033 #07 Y:1995 | 07 | 1995 | Insulate bare equipment | $1,492 | $3,107 | |
| DS0033 #06 Y:1995 | 06 | 1995 | Insulate bare equipment | $122 | $112 | |
| DS0033 #05 Y:1995 | 05 | 1995 | Insulate bare equipment | $1,377 | $104 | |
| DS0033 #04 Y:1995 | 04 | 1995 | Utilize energy-efficient belts and other improved mechanisms | $2,479 | $2,413 | |
| DS0033 #03 Y:1995 | 03 | 1995 | Install compressor air intakes in coolest locations | $631 | $300 | |
| DS0033 #02 Y:1995 | 02 | 1995 | Use most efficient type of electric motors | $5,911 | $8,264 | |
| DS0033 #01 Y:1995 | 01 | 1995 | Utilize higher efficiency lamps and/or ballasts | $3,602 | $2,709 |