| Assessment Year | 2025 |
|---|---|
| Principal Product | sausage |
| NAICS | 311611: Animal (except Poultry) Slaughtering |
| SIC | 2013: Sausages and Other Prepared Meat Products |
| Sales Range | $10 M to 50M |
| # of Employees | 201 |
| Plant Area |
32,528
ft2
|
| Annual Production | 12,589,474
lb
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $46,621 | 2,931,182 |
kWh
|
$0.016 | |
| Electricity Demand | $59,726 | 8,110 |
kW-mo/yr
|
$7.36 | |
| Electricity Fees | $9,682 | - |
|
- | |
| Natural Gas | $25,662 | 5,152 |
MMBtu
|
$4.98 | |
| Other Gas | $5,408 | 1 |
MMBtu
|
$5,407.71 | |
| Waste Disposal Costs | |||||
| Water Usage | $39,778 | 9,390 |
Tgal
|
$4.24 | |
| TOTAL YEARLY COSTS | $186,878 | ||||
| RECOMMENDED SAVINGS* | $6,625 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,986 | - | - |
$2,986
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7224: Reduce space conditioning during non-working hours | $110 | - | - | - |
$110
-
MMBtu
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,993 | $246 |
$106
6,642
kWh
|
$148
-
kW-mo/yr
|
- | $1,739 | - | |
| 04 | 2.4322: Use or replace with energy efficient substitutes | $404 | $89 |
$184
11,475
kWh
|
$464
-
kW-mo/yr
|
$(-243.8)
-
MMBtu
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $172 | $69 |
$172
10,724
kWh
|
- | - | - | - | |
| 06 | 2.2511: Insulate bare equipment | $281 | $370 | - | - |
$281
-
MMBtu
|
- | - | |
| 07 | 2.4322: Use or replace with energy efficient substitutes | $243 | $531 |
$39
2,453
kWh
|
$25
-
kW-mo/yr
|
- | - | $179 | |
| 08 | 2.7135: Install occupancy sensors | $436 | $1,102 |
$436
27,228
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $6,625 | $2,408 |
$936
58,523
kWh
|
$3,623
-
kW-mo/yr
|
$148
-
MMBtu
|
$1,739 | $179 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs