| Assessment Year | 1985 |
|---|---|
| Principal Product | GRAY IRON CASTINGS |
| NAICS |
n/a
|
| SIC | 3321: Gray and Ductile Iron Foundries |
| Sales Range | $5 M to 10M |
| # of Employees | 145 |
| Plant Area |
n/a
|
| Annual Production | 20,000
ton
|
| Production Hrs. Annual | 4,800
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $172,686 | 3,856,389 |
kWh
|
$0.045 |
| Natural Gas | $234,769 | 47,939 |
MMBtu
|
$4.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $12,143 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,143 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4323: Use optimum size and capacity equipment | $7,193 | $7,000 | - |
$7,193
-
MMBtu
|
|
| 02 | 2.7492: Use proper thickness of insulation on building envelope | $951 | $575 | - |
$951
-
MMBtu
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $433 | $150 |
$433
9,672
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $376 | - |
$376
8,499
kWh
|
- | |
| 05 | 2.2443: Re-use or recycle hot or cold process exhaust air | $3,190 | $2,100 | - |
$3,190
-
MMBtu
|
|
| TOTAL RECOMMENDED | $12,143 | $9,825 |
$809
18,171
kWh
|
$11,334
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $12,143 | $9,825 |
$809
18,171
kWh
|
$11,334
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs