Search Recommendations
ITAC logo
Search Recommendations
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,024

matching recommendations
$
$
ARC 2+ Digits Required
NAICS Navigational, measuring, electromedical, and control instruments manufacturing
SIC 2+ Digits Required
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
SU0599 #11 Y:2026 Use solar heat to make electricty $247,587 $4,721,768
SU0599 #10 Y:2026 Use or replace with energy efficient substitutes $21,494 $143,758
SU0599 #09 Y:2026 Replace existing hvac unit with high efficiency model $11,060 $26,128
SU0599 #08 Y:2026 Chill water to the highest temperature possible $79 $143
SU0599 #07 Y:2026 Conserve energy by efficient use of vending machines $3,195 $5,578
SU0599 #06 Y:2026 Install compressor air intakes in coolest locations $1,079 $1,860
SU0599 #05 Y:2026 Install / repair insulation on steam lines $671 $329
SU0599 #04 Y:2026 Implement a regular maintenance program to reduce emissions from leaky valves and pipe fittings $5,185 $1,534
SU0599 #03 Y:2026 Install / repair insulation on steam lines $2,106 $566
SU0599 #02 Y:2026 Eliminate/reduce an operation $39,205 -
SU0599 #01 Y:2026 Reduce the pressure of compressed air to the minimum required $1,426 -
CI0076 #06 Y:2026 Turn off equipment when not in use $1,037 $500
CI0076 #05 Y:2026 Reduce fluid flow rates $2,078 $8,000
CI0076 #04 Y:2026 Insulate glazing, walls, ceilings, and roofs $5,066 $10,000
CI0076 #03 Y:2026 Recharge batteries on during off-peak demand periods $7,670 $100
CI0076 #02 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $12,970 $4,600
CI0076 #01 Y:2026 Use solar heat to make electricty $81,183 $628,346
MI0470 #05 Y:2025 Utilize higher efficiency lamps and/or ballasts $4,209 $10,510
MI0470 #04 Y:2025 Install occupancy sensors $2,919 $5,000
MI0470 #03 Y:2025 Lower temperature during the winter season and vice-versa $6,557 -