Search Recommendations
ITAC logo
Search Recommendations
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

7,020

matching recommendations
$
$
ARC 2+ Digits Required
NAICS Machinery manufacturing
SIC 2+ Digits Required
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
NC0389 #04 Y:2009 Eliminate leaks in inert gas and compressed air lines/ valves $387 $100
NC0389 #03 Y:2009 Reduce the pressure of compressed air to the minimum required $627 -
NC0389 #02 Y:2009 Recover waste heat from equipment $3,172 $4,300
NC0389 #01 Y:2009 Utilize higher efficiency lamps and/or ballasts $16,752 $54,282
UM0351 #06 Y:2008 Install vinyl strip / high speed / air curtain doors $1,506 $1,660
UM0351 #05 Y:2008 Lower temperature during the winter season and vice-versa $1,656 $500
UM0351 #04 Y:2008 Improve air circulation with destratification fans / other methods $2,124 $2,800
UM0351 #03 Y:2008 Reduce the pressure of compressed air to the minimum required $2,516 $100
UM0351 #02 Y:2008 Utilize higher efficiency lamps and/or ballasts $13,706 $19,921
UM0351 #01 Y:2008 Turn off equipment when not in use $37,050 -
UD0793 #12 Y:2008 Chill water to the highest temperature possible $435 -
UD0793 #11 Y:2008 Eliminate leaks in inert gas and compressed air lines/ valves $621 $1,000
UD0793 #10 Y:2008 Utilize higher efficiency lamps and/or ballasts $1,256 $4,820
UD0793 #09 Y:2008 Reduce the pressure of compressed air to the minimum required $1,488 -
UD0793 #08 Y:2008 Replace city water with recycled water via cooling tower $2,460 $2,500
UD0793 #07 Y:2008 Meter recycled water (to reduce sewer charges) $2,970 $1,000
UD0793 #06 Y:2008 Use cooling tower or economizer to replace chiller cooling $3,114 -
UD0793 #05 Y:2008 Use adjustable frequency drive or multiple speed motors on existing system $3,799 $400
UD0793 #04 Y:2008 Shift from daytime to nighttime operation $3,855 -
UD0793 #03 Y:2008 Improve air circulation with destratification fans / other methods $3,960 $500