1,992
matching recommendations| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| IC0327 #05 Y:2025 | 05 | 2025 | Eliminate leaks in inert gas and compressed air lines/ valves | $1,732 | $1,026 |
n/a
|
| IC0327 #04 Y:2025 | 04 | 2025 | Insulate bare equipment | $1,870 | $5,460 |
n/a
|
| IC0327 #03 Y:2025 | 03 | 2025 | Reduce the pressure of compressed air to the minimum required | $3,276 | - |
n/a
|
| IC0327 #02 Y:2025 | 02 | 2025 | Adjust burners for efficient operation | $11,584 | $631 |
n/a
|
| IC0327 #01 Y:2025 | 01 | 2025 | Eliminate leaks in inert gas and compressed air lines/ valves | $2,206 | $226 |
n/a
|
| SD0676 #11 Y:2025 | 11 | 2025 | Install common header on compressors | $2,478 | $2,050 | |
| SD0676 #10 Y:2025 | 10 | 2025 | Use adjustable frequency drive or multiple speed motors on existing system | $9,179 | $8,868 | |
| SD0676 #09 Y:2025 | 09 | 2025 | Utilize a less expensive cooling method | $153,587 | $200,000 | |
| SD0676 #08 Y:2025 | 08 | 2025 | Reschedule plant operations or reduce load to avoid peaks | $143,491 | - | |
| SD0676 #07 Y:2025 | 07 | 2025 | Use adjustable frequency drive or multiple speed motors on existing system | $1,684 | $2,699 | |
| SD0676 #06 Y:2025 | 06 | 2025 | Use adjustable frequency drive or multiple speed motors on existing system | $13,821 | $7,047 | |
| SD0676 #05 Y:2025 | 05 | 2025 | Reduce the pressure of compressed air to the minimum required | $1,805 | - | |
| SD0676 #04 Y:2025 | 04 | 2025 | Use adjustable frequency drive or multiple speed motors on existing system | $39,510 | $44,993 | |
| SD0676 #03 Y:2025 | 03 | 2025 | Utilize higher efficiency lamps and/or ballasts | $2,618 | $1,911 | |
| SD0676 #02 Y:2025 | 02 | 2025 | Use battery storage for demand control | $109,396 | $5,254 | |
| SD0676 #01 Y:2025 | 01 | 2025 | Use solar heat to make electricty | $35,908 | $47,771 | |
| SJ0035 #09 Y:2025 | 09 | 2025 | Combine utility meters | $38,439 | - |
n/a
|
| SJ0035 #08 Y:2025 | 08 | 2025 | Utilize higher efficiency lamps and/or ballasts | $695 | $3,014 |
n/a
|
| SJ0035 #07 Y:2025 | 07 | 2025 | Adopt in-house material generation | $33,751 | $121,250 |
n/a
|
| SJ0035 #06 Y:2025 | 06 | 2025 | Use battery storage for demand control | $75,310 | $186,900 |
n/a
|