108

matching recommendations
$
$
ARC 2+ Digits Required
NAICS Cement manufacturing
SIC 2+ Digits Required
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
AS0571 #07 Y:2024 Install timers on light switches in little used areas $430 $987
AS0571 #06 Y:2024 Use power during off-peak periods $492 $511
AS0571 #05 Y:2024 Utilize energy-efficient belts and other improved mechanisms $5,292 $908
AS0571 #04 Y:2024 Utilize higher efficiency lamps and/or ballasts $16,525 $34,427
AS0571 #03 Y:2024 Pay bills on time to avoid late fees $22,882 $38
AS0571 #02 Y:2024 Upgrade controls on compressors $61,102 $20,000
AS0571 #01 Y:2024 Use adjustable frequency drive or multiple speed motors on existing system $81,526 $55,952
UF0582 #12 Y:2022 Level one – add communication using iiot devices to existing control system to modify operations $333,010 -
UF0582 #11 Y:2022 Improve air circulation with destratification fans / other methods $14,868 $12,700
UF0582 #10 Y:2022 Install timers on light switches in little used areas $16,853 $7,275
UF0582 #09 Y:2022 Eliminate or reduce compressed air usage $19,379 -
UF0582 #08 Y:2022 Eliminate leaks in inert gas and compressed air lines/ valves $22,408 $756
UF0582 #07 Y:2022 Minimize condenser cooling water temperature $32,856 $29,990
UF0582 #06 Y:2022 Utilize higher efficiency lamps and/or ballasts $37,793 $79,204
UF0582 #05 Y:2022 Use flue gases in radiant heater for space heating, ovens, etc $207,860 $705,580
UF0582 #04 Y:2022 Use most efficient type of electric motors $226,296 $102,253
UF0582 #03 Y:2022 Use demand controller or load shedder $506,910 $647,662
UF0582 #02 Y:2022 Recover waste heat from equipment $1,189,637 $2,090,000
UF0582 #01 Y:2022 Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat $3,357,648 $12,825,000
LS2115 #07 Y:2021 Use photocell controls $152 $147