Assessment Year | 2021 |
---|---|
Principal Product | Cement |
NAICS | 327310: Cement Manufacturing |
SIC | 3241: Cement, Hydraulic |
Sales Range | less than $500 k |
# of Employees | 6 |
Plant Area |
42,635
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 4,004
hrs
|
Location (State) | Louisiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $163,935 | 1,663,200 |
kWh
|
$0.099 |
Electricity Demand | $42,373 | 14,428 |
kW-mo/yr
|
$2.94 |
TOTAL YEARLY COSTS | $206,308 | |||
RECOMMENDED SAVINGS* | $8,146 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,865 | $270 |
$2,865
28,943
kWh
|
- | |
02 | 2.7261: Install timers and/or thermostats | $527 | $75 |
$527
5,326
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $295 | $50 |
$295
2,978
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,387 | $789 |
$2,287
23,097
kWh
|
$100
-
kW-mo/yr
|
|
05 | 2.7124: Make a practice of turning off lights when not needed | $844 | $300 |
$844
8,526
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,076 | $451 |
$1,076
10,866
kWh
|
- | |
07 | 2.7134: Use photocell controls | $152 | $147 |
$152
1,533
kWh
|
- | |
TOTAL RECOMMENDED | $8,146 | $2,082 |
$8,046
81,269
kWh
|
$100
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs