Search Recommendations
ITAC logo
Search Recommendations
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

338

matching recommendations
$
$
ARC 2+ Digits Required
NAICS Adhesive manufacturing
SIC 2+ Digits Required
3+ Characters Required for Products
ID Description Yearly
Savings
Imp
Cost
UD1128 #07 Y:2026 Eliminate leaks in inert gas and compressed air lines/ valves $7,002 $828
UD1128 #06 Y:2026 Eliminate or reduce compressed air usage $8,922 -
UD1128 #05 Y:2026 Install vinyl strip / high speed / air curtain doors $172 $600
UD1128 #04 Y:2026 Reduce ventilation air $31,291 -
UD1128 #03 Y:2026 Use separate switches on perimeter lighting which may be turned off when natural light is available $2,524 -
UD1128 #02 Y:2026 Use adjustable frequency drive or multiple speed motors on existing system $24,321 -
UD1128 #01 Y:2026 Change rate schedules or other changes in utility service $29,465 -
MZ0386 #09 Y:2025 Lower temperature during the winter season and vice-versa $2,220 $1,050
MZ0386 #08 Y:2025 Recover waste heat from equipment $12,321 $23,000
MZ0386 #07 Y:2025 Chill water to the highest temperature possible $35,692 $43,968
MZ0386 #06 Y:2025 Chill water to the highest temperature possible $11,303 $10,592
MZ0386 #05 Y:2025 Replace existing chiller with high efficiency model $3,080 $12,700
MZ0386 #04 Y:2025 Replace existing hvac unit with high efficiency model $38,194 $140,000
MZ0386 #03 Y:2025 Replace existing chiller with high efficiency model $17,351 $65,000
MZ0386 #02 Y:2025 Utilize energy-efficient belts and other improved mechanisms $1,842 -
MZ0386 #01 Y:2025 Eliminate leaks in inert gas and compressed air lines/ valves $5,040 $3,750
MU0065 #19 Y:2025 Use solar heat to make electricty $64,482 $677,600
MU0065 #18 Y:2025 Close holes and openings in building such as broken windows $703 -
MU0065 #17 Y:2025 Reduce space conditioning during non-working hours $3,384 -
MU0065 #16 Y:2025 Utilize higher efficiency lamps and/or ballasts $54 $669