1,135
matching recommendations| ID | # | Year | Description | Yearly Savings |
Implementation
Imp Cost |
Status |
|---|---|---|---|---|---|---|
| NC0438 #02 Y:2011 | 02 | 2011 | Use heat from boiler blowdown to preheat boiler feed water | $8,972 | $7,800 | |
| NC0438 #01 Y:2011 | 01 | 2011 | Replace purchased steam with other energy source | $62,448 | $94,000 | |
| IC0182 #15 Y:2011 | 15 | 2011 | Conserve energy by efficient use of vending machines | $110 | - | |
| IC0182 #14 Y:2011 | 14 | 2011 | Optimize plant power factor | $3,378 | $20,932 | |
| IC0182 #13 Y:2011 | 13 | 2011 | Minimize operation of equipment maintained in standby condition | $379 | $379 | |
| IC0182 #12 Y:2011 | 12 | 2011 | Use optimum size and capacity equipment | $1,314 | $1,318 | |
| IC0182 #11 Y:2011 | 11 | 2011 | Install compressor air intakes in coolest locations | $2,294 | $921 | |
| IC0182 #10 Y:2011 | 10 | 2011 | Install automatic stack damper | $5,217 | $50,324 | |
| IC0182 #09 Y:2011 | 09 | 2011 | Reduce combustion air flow to optimum | $2,442 | $311 | |
| IC0182 #08 Y:2011 | 08 | 2011 | Analyze flue gas for proper air/fuel ratio | $950 | $311 | |
| IC0182 #07 Y:2011 | 07 | 2011 | Install / repair insulation on steam lines | $4,314 | $5,489 | |
| IC0182 #06 Y:2011 | 06 | 2011 | Use most efficient type of electric motors | $3,070 | - | |
| IC0182 #05 Y:2011 | 05 | 2011 | Develop a repair/replace policy | $2,734 | $11,001 | |
| IC0182 #04 Y:2011 | 04 | 2011 | Utilize higher efficiency lamps and/or ballasts | $9,045 | $43,859 | |
| IC0182 #03 Y:2011 | 03 | 2011 | Utilize higher efficiency lamps and/or ballasts | $273 | - | |
| IC0182 #02 Y:2011 | 02 | 2011 | Utilize higher efficiency lamps and/or ballasts | $2,306 | $672 | |
| IC0182 #01 Y:2011 | 01 | 2011 | Utilize higher efficiency lamps and/or ballasts | $75 | $116 | |
| UM0386 #08 Y:2010 | 08 | 2010 | Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $16,332 | $92,500 | |
| UM0386 #07 Y:2010 | 07 | 2010 | Change rate schedules or other changes in utility service | $982 | $10 | |
| UM0386 #06 Y:2010 | 06 | 2010 | Recover waste heat from equipment | $2,285 | $1,000 |