| Assessment Year | 2026 |
|---|---|
| Principal Product | Complete Windows |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $500 k to 1M |
| # of Employees | 275 |
| Plant Area |
195,000
ft2
|
| Annual Production | 715,000
units
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $388,870 | 7,556,752 |
kWh
|
$0.051 |
| Electricity Demand | $327,052 | 19,219 |
kW-mo/yr
|
$17.02 |
| Electricity Fees | $75,370 | - |
|
- |
| Natural Gas | $41,035 | 3,889 |
MMBtu
|
$10.55 |
| TOTAL YEARLY COSTS | $832,327 | |||
| RECOMMENDED SAVINGS* | $28,939 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $8,072 | $2,625 |
$8,072
156,742
kWh
|
- | - | |
| 02 | 2.4224: Upgrade controls on compressors | $6,483 | $3,310 |
$4,109
79,788
kWh
|
$2,374
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,788 | $22,779 |
$3,507
68,105
kWh
|
$2,281
-
kW-mo/yr
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,126 | $980 |
$2,611
50,693
kWh
|
$1,515
-
kW-mo/yr
|
- | |
| 05 | 2.6232: Install set-back timers | $2,574 | $1,200 | - | - |
$2,574
-
MMBtu
|
|
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,391 | $720 |
$880
17,089
kWh
|
$511
-
kW-mo/yr
|
- | |
| 07 | 2.4239: Eliminate or reduce compressed air usage | $505 | $1,917 |
$318
6,173
kWh
|
$187
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $28,939 | $33,531 |
$19,497
378,590
kWh
|
$6,868
-
kW-mo/yr
|
$2,574
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs