Assessment Year | 2025 |
---|---|
Principal Product | Offering Envelops and Paper Goods |
NAICS | 322230: Stationery Product Manufacturing |
SIC | 2677: Envelopes |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
72,000
ft2
|
Annual Production | 200,000,000
units
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $57,121 | 879,709 |
kWh
|
$0.065 | |
Electricity Demand | $52,483 | 3,080 |
kW-mo/yr
|
$17.04 | |
Electricity Fees | $4,645 | - |
|
- | |
Fuel Oil #1 | $41,379 | 1,807 |
MMBtu
|
$22.90 | |
Waste Disposal Costs | |||||
Water Usage | $2,669 | 119 |
Tgal
|
$22.43 | |
Water Disposal | $1,587 | 119 |
Tgal
|
$13.34 | |
TOTAL YEARLY COSTS | $159,884 | ||||
RECOMMENDED SAVINGS* | $21,421 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #1 Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $11,496 | $6,800 | - | - |
$11,496
-
MMBtu
|
- | |
02 | 2.7135: Install occupancy sensors | $2,726 | $1,870 |
$1,550
23,890
kWh
|
$1,176
-
kW-mo/yr
|
- | - | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,689 | $3,615 | - | - |
$2,689
-
MMBtu
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,592 | $7,384 |
$1,432
22,067
kWh
|
$1,160
-
kW-mo/yr
|
- | - | |
05 | 2.4157: Establish a predictive maintenance program | $898 | $3,200 |
$1,118
17,223
kWh
|
$852
-
kW-mo/yr
|
- | $(-1,072.0) | |
06 | 2.4224: Upgrade controls on compressors | $828 | $937 |
$521
8,029
kWh
|
$307
-
kW-mo/yr
|
- | - | |
07 | 2.4239: Eliminate or reduce compressed air usage | $192 | $572 |
$107
1,644
kWh
|
$85
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $21,421 | $24,378 |
$4,728
72,853
kWh
|
$3,580
-
kW-mo/yr
|
$14,185
-
MMBtu
|
$(-1,072.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #1 Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs