ITAC Assessment: WV0687
ITAC logo
ITAC Assessment: WV0687
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Offering Envelops and Paper Goods
NAICS 322230: Stationery Product Manufacturing
SIC 2677: Envelopes
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area 72,000
ft2
Annual Production 200,000,000
units
Production Hrs. Annual 4,160
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $57,121 879,709
kWh
Electricity Demand $52,483 3,080
kW-mo/yr
Electricity Fees $4,645 -
Fuel Oil #1 $41,379 1,807
MMBtu
Waste Disposal Costs
Water Usage $2,669 119
Tgal
Water Disposal $1,587 119
Tgal
TOTAL YEARLY COSTS $159,884
RECOMMENDED SAVINGS* $21,421 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Fuel Oil #1 Savings Personnel Changes Savings
01 2.2449: Recover heat from exhausted steam, hot air or hot water $11,496 $6,800 - - $11,496
-
MMBtu
-
02 2.7135: Install occupancy sensors $2,726 $1,870 $1,550
23,890
kWh
$1,176
-
kW-mo/yr
- -
03 2.1233: Analyze flue gas for proper air/fuel ratio $2,689 $3,615 - - $2,689
-
MMBtu
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,592 $7,384 $1,432
22,067
kWh
$1,160
-
kW-mo/yr
- -
05 2.4157: Establish a predictive maintenance program $898 $3,200 $1,118
17,223
kWh
$852
-
kW-mo/yr
- $(-1,072.0)
06 2.4224: Upgrade controls on compressors $828 $937 $521
8,029
kWh
$307
-
kW-mo/yr
- -
07 2.4239: Eliminate or reduce compressed air usage $192 $572 $107
1,644
kWh
$85
-
kW-mo/yr
- -
TOTAL RECOMMENDED $21,421 $24,378 $4,728
72,853
kWh
$3,580
-
kW-mo/yr
$14,185
-
MMBtu
$(-1,072.0)
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Fuel Oil #1 Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs