ITAC Assessment: WV0680
ITAC logo
ITAC Assessment: WV0680
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Conveyor Accessories
NAICS 333922: Conveyor and Conveying Equipment Manufacturing
SIC 3532: Mining Machinery and Equipment, Except Oil and Gas Field Machinery and Equipment
Sales Range $50
M
to 100
M
# of Employees 286
Plant Area 96,411
ft2
Annual Production 650,000
lb
Production Hrs. Annual 8,736
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $231,324 3,044,576
kWh
Electricity Demand $79,764 7,610
kW-mo/yr
Electricity Fees $16,668 -
Natural Gas $58,839 4,964
MMBtu
TOTAL YEARLY COSTS $386,595
RECOMMENDED SAVINGS* $123,390 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $71,035 $115,528 $57,757
759,960
kWh
$13,278
-
kW-mo/yr
-
02 2.2511: Insulate bare equipment $19,535 $2,495 $15,437
201,112
kWh
$4,098
-
kW-mo/yr
-
03 2.7314: Reduce ventilation air $13,841 $6,504 - - $13,841
-
MMBtu
04 2.4322: Use or replace with energy efficient substitutes $9,835 $33,120 $7,770
102,231
kWh
$2,065
-
kW-mo/yr
-
05 2.4224: Upgrade controls on compressors $2,106 $5,245 $1,561
20,543
kWh
$545
-
kW-mo/yr
-
06 2.7135: Install occupancy sensors $1,628 $5,289 $1,104
14,523
kWh
$524
-
kW-mo/yr
-
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,360 $4,307 $957
12,593
kWh
$403
-
kW-mo/yr
-
08 2.6231: Utilize controls to operate equipment only when needed $1,314 $1,343 $1,314
17,292
kWh
- -
09 2.4221: Install compressor air intakes in coolest locations $1,296 $5,010 $471
6,196
kWh
$126
-
kW-mo/yr
$699
-
MMBtu
10 2.4239: Eliminate or reduce compressed air usage $1,052 $1,082 $905
11,907
kWh
$147
-
kW-mo/yr
-
11 2.4231: Reduce the pressure of compressed air to the minimum required $388 $424 $304
4,001
kWh
$84
-
kW-mo/yr
-
TOTAL RECOMMENDED $123,390 $180,347 $87,580
1,150,358
kWh
$21,270
-
kW-mo/yr
$14,540
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs