ITAC Assessment: WV0660
ITAC logo
ITAC Assessment: WV0660
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Hydraulic Cylinders
NAICS 333611: Turbine and Turbine Generator Set Units Manufacturing
SIC 3511: Steam, Gas, and Hydraulic Turbines, and Turbine Generator Set Units
Sales Range $50
M
to 100
M
# of Employees 120
Plant Area 239,483
ft2
Annual Production 120,000
pieces
Production Hrs. Annual 6,318
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $442,427 7,224,092
kWh
Electricity Demand $161,335 15,292
kW-mo/yr
Natural Gas $136,755 15,121
MMBtu
TOTAL YEARLY COSTS $740,517
RECOMMENDED SAVINGS* $79,508 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7447: Install vinyl strip / high speed / air curtain doors $22,781 $18,776 $13,499
216,983
kWh
$3,650
-
kW-mo/yr
$5,632
-
MMBtu
02 2.7135: Install occupancy sensors $19,324 $10,600 $14,482
236,626
kWh
$4,842
-
kW-mo/yr
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $9,000 $9,158 $6,584
107,587
kWh
$2,416
-
kW-mo/yr
-
04 2.6232: Install set-back timers $8,713 $1,125 $2,662
43,499
kWh
$528
-
kW-mo/yr
$5,523
-
MMBtu
05 2.2511: Insulate bare equipment $8,339 $2,225 $3,525
57,598
kWh
$954
-
kW-mo/yr
$3,860
-
MMBtu
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,956 $1,323 $4,500
73,526
kWh
$1,456
-
kW-mo/yr
-
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $3,033 $2,884 $2,389
39,049
kWh
$644
-
kW-mo/yr
-
08 2.4239: Eliminate or reduce compressed air usage $1,979 $4,576 $1,557
25,439
kWh
$422
-
kW-mo/yr
-
09 2.4231: Reduce the pressure of compressed air to the minimum required $383 $104 $299
4,883
kWh
$84
-
kW-mo/yr
-
TOTAL RECOMMENDED $79,508 $50,771 $49,497
805,190
kWh
$14,996
-
kW-mo/yr
$15,015
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs