| Assessment Year | 2024 |
|---|---|
| Principal Product | Hydraulic Cylinders |
| NAICS | 333611: Turbine and Turbine Generator Set Units Manufacturing |
| SIC | 3511: Steam, Gas, and Hydraulic Turbines, and Turbine Generator Set Units |
| Sales Range | $50 M to 100M |
| # of Employees | 120 |
| Plant Area |
239,483
ft2
|
| Annual Production | 120,000
pieces
|
| Production Hrs. Annual | 6,318
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $442,427 | 7,224,092 |
kWh
|
$0.061 |
| Electricity Demand | $161,335 | 15,292 |
kW-mo/yr
|
$10.55 |
| Natural Gas | $136,755 | 15,121 |
MMBtu
|
$9.04 |
| TOTAL YEARLY COSTS | $740,517 | |||
| RECOMMENDED SAVINGS* | $79,508 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $37,403 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $22,781 | $18,776 |
$13,499
216,983
kWh
|
$3,650
-
kW-mo/yr
|
$5,632
-
MMBtu
|
|
| 02 | 2.7135: Install occupancy sensors | $19,324 | $10,600 |
$14,482
236,626
kWh
|
$4,842
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,000 | $9,158 |
$6,584
107,587
kWh
|
$2,416
-
kW-mo/yr
|
- | |
| 04 | 2.6232: Install set-back timers | $8,713 | $1,125 |
$2,662
43,499
kWh
|
$528
-
kW-mo/yr
|
$5,523
-
MMBtu
|
|
| 05 | 2.2511: Insulate bare equipment | $8,339 | $2,225 |
$3,525
57,598
kWh
|
$954
-
kW-mo/yr
|
$3,860
-
MMBtu
|
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,956 | $1,323 |
$4,500
73,526
kWh
|
$1,456
-
kW-mo/yr
|
- | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,033 | $2,884 |
$2,389
39,049
kWh
|
$644
-
kW-mo/yr
|
- | |
| 08 | 2.4239: Eliminate or reduce compressed air usage | $1,979 | $4,576 |
$1,557
25,439
kWh
|
$422
-
kW-mo/yr
|
- | |
| 09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $383 | $104 |
$299
4,883
kWh
|
$84
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $79,508 | $50,771 |
$49,497
805,190
kWh
|
$14,996
-
kW-mo/yr
|
$15,015
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $37,403 | $21,395 |
$21,516
351,581
kWh
|
$6,504
-
kW-mo/yr
|
$9,383
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs