ITAC Assessment: WV0638
ITAC logo
ITAC Assessment: WV0638
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product Eye Care Contact Lenses Distribution Center
NAICS 493110: General Warehousing and Storage
SIC 4225: General Warehousing and Storage
Sales Range $50
M
to 100
M
# of Employees 238
Plant Area 204,082
ft2
Annual Production 75,000
units
Production Hrs. Annual 6,240
hrs
Location (State) Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $180,172 2,281,392
kWh
Electricity Demand $16,016 4,959
kW-mo/yr
Electricity Fees $1,586 -
Natural Gas $8,108 696
MMBtu
TOTAL YEARLY COSTS $205,882
RECOMMENDED SAVINGS* $30,721 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,251

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7241: Install outside air damper / economizer on hvac unit $9,119 $41,800 $8,773
111,047
kWh
$346
-
kW-mo/yr
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $8,432 $10,200 $7,805
98,801
kWh
$627
-
kW-mo/yr
-
03 2.7226: Use computer programs to optimize hvac performance $7,943 $18,226 $3,689
46,700
kWh
$291
-
kW-mo/yr
$3,963
-
MMBtu
04 2.7447: Install vinyl strip / high speed / air curtain doors $2,424 $11,600 $(-60.0)
(-763)
kWh
- $2,484
-
MMBtu
05 2.4221: Install compressor air intakes in coolest locations $923 $2,323 $22
284
kWh
$3
-
kW-mo/yr
$898
-
MMBtu
06 2.4322: Use or replace with energy efficient substitutes $674 $2,060 $629
7,961
kWh
$45
-
kW-mo/yr
-
07 2.7228: Avoid introducing hot, humid, or dirty air into hvac system $631 $2,910 $586
7,424
kWh
$45
-
kW-mo/yr
-
08 2.4224: Upgrade controls on compressors $484 $2,350 $366
4,631
kWh
$118
-
kW-mo/yr
-
09 2.4239: Eliminate or reduce compressed air usage $90 $100 $84
1,065
kWh
$6
-
kW-mo/yr
-
TOTAL RECOMMENDED $30,721 $91,569 $21,894
277,150
kWh
$1,482
-
kW-mo/yr
$7,345
-
MMBtu
TOTAL IMPLEMENTED $12,251 $26,870 $9,044
114,488
kWh
$723
-
kW-mo/yr
$2,484
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs