Assessment Year | 2016 |
---|---|
Principal Product | Mining Machinery |
NAICS | 333131: Mining Machinery and Equipment Manufacturing |
SIC | 3532: Mining Machinery and Equipment, Except Oil and Gas Field Machinery and Equipment |
Sales Range | $100 M to 500M |
# of Employees | 137 |
Plant Area |
80,000
ft2
|
Annual Production | 100
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $167,690 | 1,889,787 |
kWh
|
$0.089 |
Electricity Demand | $37,837 | 6,943 |
kW-mo/yr
|
$5.45 |
Electricity Fees | $5,226 | - |
|
- |
Natural Gas | $75,255 | 9,579 |
MMBtu
|
$7.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $81,377 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $5,045 | $7,350 | - | - | $5,045 | - | - | |
02 | 2.7313: Recycle air for heating, ventilation and air conditioning | $19,178 | $60,000 | - | - | - |
$19,178
-
MMBtu
|
- | |
03 | 2.7224: Reduce space conditioning during non-working hours | $1,523 | - |
$918
10,312
kWh
|
- | - |
$605
-
MMBtu
|
- | |
04 | 2.4322: Use or replace with energy efficient substitutes | $5,569 | $3,000 |
$3,999
44,928
kWh
|
$1,570
-
kW-mo/yr
|
- | - | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,706 | $750 | - | - | - |
$1,706
-
MMBtu
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $43,798 | $34,110 |
$44,116
495,686
kWh
|
$4,812
-
kW-mo/yr
|
- | - | $(-5,130.0) | |
07 | 2.7135: Install occupancy sensors | $849 | $175 |
$849
9,540
kWh
|
- | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $495 | $707 |
$344
3,868
kWh
|
$29
-
kW-mo/yr
|
- | - | $122 | |
09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,047 | $1,200 |
$1,047
11,760
kWh
|
- | - | - | - | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $315 | - |
$315
3,540
kWh
|
- | - | - | - | |
11 | 2.4221: Install compressor air intakes in coolest locations | $309 | $710 |
$309
3,474
kWh
|
- | - | - | - | |
12 | 2.6218: Turn off equipment when not in use | $1,351 | - |
$1,351
15,185
kWh
|
- | - | - | - | |
13 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $192 | - |
$192
2,155
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $81,377 | $108,002 |
$53,440
600,448
kWh
|
$6,411
-
kW-mo/yr
|
$5,045 |
$21,489
-
MMBtu
|
$(-5,008.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs