| Assessment Year | 2022 |
|---|---|
| Principal Product | Wood cabinets, casework |
| NAICS | 321999: All Other Miscellaneous Wood Product Manufacturing |
| SIC | 2499: Wood Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 48 |
| Plant Area |
47,230
ft2
|
| Annual Production | 25,000
units
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $63,749 | 1,493,992 |
kWh
|
$0.043 | |
| Electricity Demand | $60,350 | 4,149 |
kW-mo/yr
|
$14.55 | |
| Electricity Fees | $129,466 | - |
|
- | |
| Natural Gas | $6,080 | 667 |
MMBtu
|
$9.12 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,791 | 135 |
Tgal
|
$13.27 | |
| TOTAL YEARLY COSTS | $261,436 | ||||
| RECOMMENDED SAVINGS* | $19,550 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $8,399 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $7,261 | $14,000 |
$4,592
100,701
kWh
|
- |
$2,669
-
MMBtu
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,860 | $7,799 |
$1,823
39,983
kWh
|
$2,037
-
kW-mo/yr
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,701 | $160 |
$1,377
30,198
kWh
|
$1,324
-
kW-mo/yr
|
- | - | |
| 04 | 2.1321: Replace fossil fuel equipment with electrical equipment | $2,566 | $12,480 |
$(-1,768.0)
(-38,774)
kWh
|
$(-1,688.0)
-
kW-mo/yr
|
$6,022
-
MMBtu
|
- | |
| 05 | 2.4224: Upgrade controls on compressors | $1,324 | $3,185 |
$422
9,253
kWh
|
$902
-
kW-mo/yr
|
- | - | |
| 06 | 2.6218: Turn off equipment when not in use | $792 | $3,586 |
$792
17,370
kWh
|
- | - | - | |
| 07 | 2.4239: Eliminate or reduce compressed air usage | $454 | $467 |
$236
5,165
kWh
|
$218
-
kW-mo/yr
|
- | - | |
| 08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $301 | $40 |
$155
3,407
kWh
|
$146
-
kW-mo/yr
|
- | - | |
| 09 | 2.4151: Develop a repair/replace policy | $291 | $1,347 |
$207
4,529
kWh
|
$204
-
kW-mo/yr
|
- | $(-120.0) | |
| TOTAL RECOMMENDED | $19,550 | $43,064 |
$7,836
171,832
kWh
|
$3,143
-
kW-mo/yr
|
$8,691
-
MMBtu
|
$(-120.0) | ||
| TOTAL IMPLEMENTED | $8,399 | $13,399 |
$4,590
100,652
kWh
|
$3,929
-
kW-mo/yr
|
- | $(-120.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs