| Assessment Year | 1995 |
|---|---|
| Principal Product | Dart Boards |
| NAICS |
n/a
|
| SIC | 3944: Games, Toys, and Children's Vehicles, Except Dolls and Bicycles |
| Sales Range | $10 M to 50M |
| # of Employees | 160 |
| Plant Area |
170,000
ft2
|
| Annual Production | 608,000
pieces
|
| Production Hrs. Annual | 2,250
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $157,380 | 2,251,759 |
kWh
|
$0.070 |
| Natural Gas | $24,643 | 6,536 |
MMBtu
|
$3.77 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $10,652 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $911 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7135: Install occupancy sensors | $2,689 | $975 |
$2,689
38,394
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,268 | $6,300 |
$1,268
18,171
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,571 | $2,665 |
$1,571
22,567
kWh
|
|
| 04 | 2.7144: Install spectral reflectors / delamp | $786 | - |
$786
11,137
kWh
|
|
| 05 | 2.2621: Modify refrigeration system to operate at a lower pressure | $1,698 | $5,500 |
$1,698
24,326
kWh
|
|
| 06 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $690 | $1,000 |
$690
9,965
kWh
|
|
| 07 | 2.4221: Install compressor air intakes in coolest locations | $371 | $800 |
$371
5,275
kWh
|
|
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $125 | $30 |
$125
1,758
kWh
|
|
| 09 | 2.7241: Install outside air damper / economizer on hvac unit | $911 | $4,200 |
$911
13,189
kWh
|
|
| 10 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $543 | $525 |
$543
7,913
kWh
|
|
| TOTAL RECOMMENDED | $10,652 | $21,995 |
$10,652
152,695
kWh
|
||
| TOTAL IMPLEMENTED | $911 | $30 |
$911
12,895
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs