Assessment Year | 2022 |
---|---|
Principal Product | Outdoor Sporting Goods Distribution |
NAICS | 493110: General Warehousing and Storage |
SIC | 4225: General Warehousing and Storage |
Sales Range | $50 M to 100M |
# of Employees | 425 |
Plant Area |
1,167,604
ft2
|
Annual Production | 20,000,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $316,606 | 5,685,300 |
kWh
|
$0.056 |
Electricity Demand | $155,222 | 9,379 |
kW-mo/yr
|
$16.55 |
Electricity Fees | $2,388 | - |
|
- |
Natural Gas | $54,599 | 23,894 |
MMBtu
|
$2.29 |
TOTAL YEARLY COSTS | $528,815 | |||
RECOMMENDED SAVINGS* | $129,124 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $83,521 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $73,145 | $29,680 |
$51,978
933,169
kWh
|
$21,167
-
kW-mo/yr
|
- | - | |
02 | 2.7232: Replace existing hvac unit with high efficiency model | $28,641 | $112,444 |
$(-6,489.0)
(-116,492)
kWh
|
$(-2,648.0)
-
kW-mo/yr
|
$37,778
-
MMBtu
|
- | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,687 | $17,469 |
$7,523
135,067
kWh
|
$5,164
-
kW-mo/yr
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,879 | $893 |
$4,893
87,843
kWh
|
$1,986
-
kW-mo/yr
|
- | - | |
05 | 2.4224: Upgrade controls on compressors | $3,011 | $6,065 |
$2,035
36,543
kWh
|
$976
-
kW-mo/yr
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $1,547 | $2,323 |
$485
8,703
kWh
|
$199
-
kW-mo/yr
|
$863
-
MMBtu
|
- | |
07 | 2.2515: Use optimum thickness insulation | $1,264 | $5,280 | - | - |
$1,264
-
MMBtu
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $997 | $120 |
$716
12,860
kWh
|
$281
-
kW-mo/yr
|
- | - | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $734 | $323 |
$519
9,317
kWh
|
$215
-
kW-mo/yr
|
- | - | |
10 | 2.4151: Develop a repair/replace policy | $219 | $1,027 |
$287
5,144
kWh
|
$116
-
kW-mo/yr
|
- | $(-184.0) | |
TOTAL RECOMMENDED | $129,124 | $175,624 |
$61,947
1,112,154
kWh
|
$27,456
-
kW-mo/yr
|
$39,905
-
MMBtu
|
$(-184.0) | ||
TOTAL IMPLEMENTED | $83,521 | $34,366 |
$58,878
1,057,036
kWh
|
$23,964
-
kW-mo/yr
|
$863
-
MMBtu
|
$(-184.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs