Assessment Year | 2021 |
---|---|
Principal Product | Spun Yarn |
NAICS | 313110: Fiber, Yarn, and Thread Mills |
SIC | 2281: Yarn Spinning Mills |
Sales Range | $10 M to 50M |
# of Employees | 500 |
Plant Area |
361,000
ft2
|
Annual Production | 18,200,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,215,059 | 56,612,285 |
kWh
|
$0.021 |
Electricity Demand | $1,936,237 | 119,172 |
kW-mo/yr
|
$16.25 |
TOTAL YEARLY COSTS | $3,151,296 | |||
RECOMMENDED SAVINGS* | $487,404 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $49,755 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $399,970 | $573,165 |
$149,297
6,944,063
kWh
|
$250,673
-
kW-mo/yr
|
- | - | |
02 | 2.4224: Upgrade controls on compressors | $37,679 | $34,222 |
$18,437
857,520
kWh
|
$19,242
-
kW-mo/yr
|
- | - | |
03 | 2.4157: Establish a predictive maintenance program | $14,148 | $1,000 |
$8,668
403,145
kWh
|
$8,970
-
kW-mo/yr
|
$(-3,490.0) | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,396 | $38,385 |
$6,187
287,753
kWh
|
$7,209
-
kW-mo/yr
|
- | - | |
05 | 2.4151: Develop a repair/replace policy | $7,526 | $5,317 |
$3,973
184,769
kWh
|
$4,193
-
kW-mo/yr
|
- | $(-640.0) | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,463 | $2,884 |
$3,644
169,474
kWh
|
$3,819
-
kW-mo/yr
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,283 | $450 |
$1,609
74,825
kWh
|
$1,674
-
kW-mo/yr
|
- | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $2,815 | $60 |
$1,385
64,422
kWh
|
$1,430
-
kW-mo/yr
|
- | - | |
09 | 2.4239: Eliminate or reduce compressed air usage | $1,124 | $1,083 |
$555
25,824
kWh
|
$569
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $487,404 | $656,566 |
$193,755
9,011,795
kWh
|
$297,779
-
kW-mo/yr
|
$(-3,490.0) | $(-640.0) | ||
TOTAL IMPLEMENTED | $49,755 | $49,179 |
$26,021
1,210,212
kWh
|
$27,864
-
kW-mo/yr
|
$(-3,490.0) | $(-640.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs