Assessment Year 2021
Principal Product Drywall
NAICS 327420: Gypsum Product Manufacturing
SIC 3275: Gypsum Products
Sales Range $50
M
to 100
M
# of Employees 112
Plant Area 490,000
ft2
Annual Production 4,800,000
units
Production Hrs. Annual 8,736
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,003,456 28,616,874
kWh
Electricity Demand $922,190 55,244
kW-mo/yr
Electricity Fees $4,140 -
Natural Gas $2,705,610 2,443,851
MMBtu
TOTAL YEARLY COSTS $4,635,396
RECOMMENDED SAVINGS* $525,978 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $335,278 $8,838 $(-4,623.0)
(-131,713)
kWh
$(-3,021.0)
-
kW-mo/yr
$344,002
-
MMBtu
$(-1,080.0)
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $153,514 $84,253 $92,863
2,645,667
kWh
$60,651
-
kW-mo/yr
- -
03 2.4151: Develop a repair/replace policy $11,834 $1,018 $7,737
220,431
kWh
$5,057
-
kW-mo/yr
- $(-960.0)
04 2.2511: Insulate bare equipment $10,297 $13,192 - - $10,297
-
MMBtu
-
05 2.4224: Upgrade controls on compressors $8,141 $1,391 $5,166
147,170
kWh
$2,975
-
kW-mo/yr
- -
06 2.4221: Install compressor air intakes in coolest locations $3,058 $3,394 $1,856
52,863
kWh
$1,202
-
kW-mo/yr
- -
07 2.4239: Eliminate or reduce compressed air usage $1,613 $30 $979
27,883
kWh
$634
-
kW-mo/yr
- -
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,223 $1,300 $739
21,043
kWh
$484
-
kW-mo/yr
- -
09 2.4239: Eliminate or reduce compressed air usage $546 $525 $329
9,630
kWh
$217
-
kW-mo/yr
- -
10 2.7241: Install outside air damper / economizer on hvac unit $474 $1,450 $374
10,648
kWh
$100
-
kW-mo/yr
- -
TOTAL RECOMMENDED $525,978 $115,391 $105,420
3,003,622
kWh
$68,299
-
kW-mo/yr
$354,299
-
MMBtu
$(-2,040.0)
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs