| Assessment Year | 2019 |
|---|---|
| Principal Product | Processed Rubber |
| NAICS | 325211: Plastics Material and Resin Manufacturing |
| SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
| Sales Range | $10 M to 50M |
| # of Employees | 57 |
| Plant Area |
2,700,000
ft2
|
| Annual Production | 40,000,000
units
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $510,057 | 6,381,000 |
kWh
|
$0.080 | |
| Electricity Demand | $67,625 | 15,266 |
kW-mo/yr
|
$4.43 | |
| Natural Gas | $64,385 | 12,776 |
MMBtu
|
$5.04 | |
| Waste Disposal Costs | |||||
| Water Usage | $12,648 | 1,968 |
Tgal
|
$6.43 | |
| Water Disposal | $8,712 | 1,968 |
Tgal
|
$4.43 | |
| TOTAL YEARLY COSTS | $663,427 | ||||
| RECOMMENDED SAVINGS* | $70,962 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $25,014 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.1172: Revise raw material specs | $26,910 | $52,500 | - | - | - | - | - | $26,910 | |
| 02 | 2.7135: Install occupancy sensors | $14,108 | $10,162 |
$12,433
155,606
kWh
|
$1,675
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.1321: Replace fossil fuel equipment with electrical equipment | $9,375 | $3,276 |
$(-3,082.0)
(-38,571)
kWh
|
$(-244.0)
-
kW-mo/yr
|
$12,701
-
MMBtu
|
- | - | - | |
| 04 | 2.4224: Upgrade controls on compressors | $9,048 | $8,000 |
$9,048
113,243
kWh
|
- | - | - | - | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,691 | $46 |
$3,421
42,812
kWh
|
$270
-
kW-mo/yr
|
- | - | - | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,235 | - |
$2,996
37,503
kWh
|
$239
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.4151: Develop a repair/replace policy | $2,811 | $540 |
$2,773
34,701
kWh
|
$222
-
kW-mo/yr
|
- | - | - | $(-184.0) | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,169 | $1,725 |
$1,014
12,693
kWh
|
$155
-
kW-mo/yr
|
- | - | - | - | |
| 09 | 3.4151: Minimize water usage | $615 | $2,100 | - | - | - |
$441
-
Tgal
|
$304
-
Tgal
|
$(-130.0) | |
| TOTAL RECOMMENDED | $70,962 | $78,349 |
$28,603
357,987
kWh
|
$2,317
-
kW-mo/yr
|
$12,701
-
MMBtu
|
$441
-
Tgal
|
$304
-
Tgal
|
$26,596 | ||
| TOTAL IMPLEMENTED | $25,014 | $12,473 |
$22,637
283,315
kWh
|
$2,561
-
kW-mo/yr
|
- | - | - | $(-184.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs