Assessment Year 2017
Principal Product Water
NAICS 221310: Water Supply and Irrigation Systems
SIC 4941: Water Supply
Sales Range $50
M
to 100
M
# of Employees 17
Plant Area 476,685
ft2
Annual Production 11,000,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,874,718 31,217,030
kWh
Electricity Demand $69,796 65,712
kW-mo/yr
Natural Gas $42,910 5,816
MMBtu
TOTAL YEARLY COSTS $1,987,424
RECOMMENDED SAVINGS* $169,073 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $32,860

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $108,472 $401,920 $108,472
1,804,860
kWh
- - - -
02 2.3137: Use power during off-peak periods $17,322 $2,500 - $3,562
-
kW-mo/yr
- $(-6,240.0) $20,000
03 2.7264: Interlock heating and air conditioning systems to prevent simultaneous operation $14,015 $46,500 $12,065
200,745
kWh
$983
-
kW-mo/yr
$967
-
MMBtu
- -
04 2.4151: Develop a repair/replace policy $13,726 $620 $13,714
228,180
kWh
$332
-
kW-mo/yr
- - $(-320.0)
05 2.4157: Establish a predictive maintenance program $9,424 $1,000 $10,158
169,023
kWh
$246
-
kW-mo/yr
- - $(-980.0)
06 2.7142: Utilize higher efficiency lamps and/or ballasts $3,201 $10,486 $3,106
51,688
kWh
$95
-
kW-mo/yr
- - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,913 $3,240 $2,844
47,329
kWh
$69
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $169,073 $466,266 $150,359
2,501,825
kWh
$5,287
-
kW-mo/yr
$967
-
MMBtu
$(-6,240.0) $18,700
TOTAL IMPLEMENTED $32,860 $17,226 $16,108
268,040
kWh
$3,972
-
kW-mo/yr
- $(-6,240.0) $19,020
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs