ITAC Assessment: WV0533
ITAC logo
ITAC Assessment: WV0533
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Boom Lifts and Telehandlers
NAICS 333120: Construction Machinery Manufacturing
SIC 3531: Construction Machinery and Equipment
Sales Range $1
M
to 5
M
# of Employees 1,343
Plant Area 557,000
ft2
Annual Production 500
units
Production Hrs. Annual 6,000
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,159,617 21,123,826
kWh
Natural Gas $623,070 125,547
MMBtu
TOTAL YEARLY COSTS $1,782,687
RECOMMENDED SAVINGS* $189,204 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $79,264

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
01 2.4322: Use or replace with energy efficient substitutes $82,641 $202,000 $82,641
1,505,304
kWh
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $33,898 $72,687 $33,898
617,449
kWh
- -
03 2.1221: Replace obsolete burners with more efficient ones $15,212 $35,900 - $15,212
-
MMBtu
-
04 2.4239: Eliminate or reduce compressed air usage $11,228 $2,417 $11,228
204,525
kWh
- -
05 2.4157: Establish a predictive maintenance program $9,595 $1,000 $10,478
190,851
kWh
- $(-883.0)
06 2.4224: Upgrade controls on compressors $8,986 $20,750 $8,986
163,682
kWh
- -
07 2.7135: Install occupancy sensors $8,138 $4,160 $8,138
148,236
kWh
- -
08 2.1233: Analyze flue gas for proper air/fuel ratio $5,301 $4,100 - $5,451
-
MMBtu
$(-150.0)
09 2.2522: Isolate hot or cold equipment $4,874 $5,100 $(-478.0)
(-8,712)
kWh
$5,352
-
MMBtu
-
10 2.4151: Develop a repair/replace policy $3,084 $665 $3,184
57,996
kWh
- $(-100.0)
11 2.4231: Reduce the pressure of compressed air to the minimum required $2,697 $300 $2,697
49,126
kWh
- -
12 2.7447: Install vinyl strip / high speed / air curtain doors $2,004 $2,230 - $2,004
-
MMBtu
-
13 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $770 $2,150 $770
14,021
kWh
- -
14 2.4111: Utilize energy-efficient belts and other improved mechanisms $558 - $558
10,155
kWh
- -
15 2.2511: Insulate bare equipment $218 $470 - $218
-
MMBtu
-
TOTAL RECOMMENDED $189,204 $353,929 $162,100
2,952,633
kWh
$28,237
-
MMBtu
$(-1,133.0)
TOTAL IMPLEMENTED $79,264 $117,819 $62,813
1,144,123
kWh
$17,434
-
MMBtu
$(-983.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs