Assessment Year | 2015 |
---|---|
Principal Product | Hardwood Flooring |
NAICS | 321918: Other Millwork (including Flooring) |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
150,000
ft2
|
Annual Production | 10,000
thousand feet
|
Production Hrs. Annual | 2,457
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $608,936 | 10,604,452 |
kWh
|
$0.057 |
Electricity Demand | $214,839 | 29,474 |
kW-mo/yr
|
$7.29 |
Wood | $654,618 | 116,480 |
MMBtu
|
$5.62 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $279,623 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $120,543 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Wood Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $125,552 | $301,080 |
$(-20,928.0)
(-364,597)
kWh
|
- |
$146,480
-
MMBtu
|
- | |
02 | 2.2511: Insulate bare equipment | $45,398 | $21,389 | - | - |
$45,398
-
MMBtu
|
- | |
03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $44,726 | $1,700 | - | - |
$44,758
-
MMBtu
|
$(-32.0) | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $26,154 | $21,062 |
$20,857
363,373
kWh
|
$5,297
-
kW-mo/yr
|
- | - | |
05 | 2.4157: Establish a predictive maintenance program | $18,366 | $1,000 |
$15,918
277,315
kWh
|
$5,016
-
kW-mo/yr
|
- | $(-2,568.0) | |
06 | 2.4239: Eliminate or reduce compressed air usage | $7,374 | $4,512 |
$6,280
109,414
kWh
|
$1,094
-
kW-mo/yr
|
- | - | |
07 | 2.4151: Develop a repair/replace policy | $4,518 | $879 |
$3,582
62,396
kWh
|
$1,128
-
kW-mo/yr
|
- | $(-192.0) | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,613 | - |
$2,640
45,997
kWh
|
$973
-
kW-mo/yr
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,786 | $903 |
$1,257
21,905
kWh
|
$529
-
kW-mo/yr
|
- | - | |
10 | 2.4239: Eliminate or reduce compressed air usage | $1,405 | $1,113 |
$851
14,823
kWh
|
$554
-
kW-mo/yr
|
- | - | |
11 | 2.6232: Install set-back timers | $731 | $1,164 |
$622
10,841
kWh
|
$109
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $279,623 | $354,802 |
$31,079
541,467
kWh
|
$14,700
-
kW-mo/yr
|
$236,636
-
MMBtu
|
$(-2,792.0) | ||
TOTAL IMPLEMENTED | $120,543 | $28,148 |
$24,870
433,277
kWh
|
$8,309
-
kW-mo/yr
|
$90,156
-
MMBtu
|
$(-2,792.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Wood Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs