Assessment Year | 1995 |
---|---|
Principal Product | Sealing Devices, Piston Rings |
NAICS |
n/a
|
SIC | 3592: Carburetors, Pistons, Piston Rings, and Valves |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
163,350
ft2
|
Annual Production | 187,000
pieces
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $183,841 | 3,063,306 |
kWh
|
$0.060 |
Natural Gas | $64,323 | 15,148 |
MMBtu
|
$4.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,031 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,493 | $2,529 |
$5,493
91,442
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $4,310 | $7,520 |
$4,310
71,805
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,488 | $5,143 |
$3,488
58,030
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $769 | $10 |
$769
12,896
kWh
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $569 | $1,000 | - |
$569
-
MMBtu
|
|
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,402 | $40 |
$1,402
23,154
kWh
|
- | |
TOTAL RECOMMENDED | $16,031 | $16,242 |
$15,462
257,327
kWh
|
$569
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs