| Assessment Year | 2015 |
|---|---|
| Principal Product | Fabrication, Machining, Design, and Building Coil Equipment |
| NAICS | 333519: Rolling Mill and Other Metalworking Machinery Manufacturing |
| SIC | 3549: Metalworking Machinery, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
165,000
ft2
|
| Annual Production | 6
pieces
|
| Production Hrs. Annual | 4,675
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $77,616 | 1,447,200 |
kWh
|
$0.054 |
| Electricity Demand | $67,391 | 4,228 |
kW-mo/yr
|
$15.94 |
| Natural Gas | $58,708 | 7,344 |
MMBtu
|
$7.99 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $26,535 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,834 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,355 | $27,692 |
$4,055
75,660
kWh
|
$3,300
-
kW-mo/yr
|
- | - | |
| 02 | 2.4322: Use or replace with energy efficient substitutes | $6,444 | $22,500 |
$3,654
68,167
kWh
|
$2,790
-
kW-mo/yr
|
- | - | |
| 03 | 2.3191: Use demand controller or load shedder | $2,630 | $5,700 | - |
$2,630
-
kW-mo/yr
|
- | - | |
| 04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,899 | $500 | - | - |
$3,004
-
MMBtu
|
$(-105.0) | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,831 | $374 |
$1,604
29,923
kWh
|
$1,227
-
kW-mo/yr
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,499 | $3,530 |
$1,112
20,752
kWh
|
$1,387
-
kW-mo/yr
|
- | - | |
| 07 | 2.4157: Establish a predictive maintenance program | $915 | $1,000 |
$1,896
35,379
kWh
|
$1,451
-
kW-mo/yr
|
- | $(-2,432.0) | |
| 08 | 2.4239: Eliminate or reduce compressed air usage | $407 | $448 |
$232
4,332
kWh
|
$175
-
kW-mo/yr
|
- | - | |
| 09 | 2.4151: Develop a repair/replace policy | $283 | $630 |
$400
7,463
kWh
|
$303
-
kW-mo/yr
|
- | $(-420.0) | |
| 10 | 2.7447: Install vinyl strip / high speed / air curtain doors | $272 | $1,250 | - | - |
$272
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $26,535 | $63,624 |
$12,953
241,676
kWh
|
$13,263
-
kW-mo/yr
|
$3,276
-
MMBtu
|
$(-2,957.0) | ||
| TOTAL IMPLEMENTED | $9,834 | $6,482 |
$5,244
97,849
kWh
|
$4,543
-
kW-mo/yr
|
$3,004
-
MMBtu
|
$(-2,957.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs