| Assessment Year | 2003 |
|---|---|
| Principal Product | Rescue Hoists, Cargo Winches, Hooks Equipment for Aerospace |
| NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
| SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 294 |
| Plant Area |
168,000
ft2
|
| Annual Production | 350
pieces
|
| Production Hrs. Annual | 2,867
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $167,589 | 1,857,871 |
kWh
|
$0.090 |
| Electricity Demand | $45,097 | 5,705 |
kW-mo/yr
|
$7.90 |
| Natural Gas | $67,883 | 7,840 |
MMBtu
|
$8.66 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $46,942 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $40,829 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $2,205 | - |
$2,205
36,204
kWh
|
- | - | |
| 02 | 2.2695: Use cascade system of recirculating during cold weather to avoid sub-cooling | $1,150 | $1,000 |
$1,150
18,884
kWh
|
- | - | |
| 03 | 2.7441: Replace broken windows and/or window sash | $2,601 | $3,036 | - | - |
$2,601
-
MMBtu
|
|
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,998 | $10,129 | - | - |
$2,998
-
MMBtu
|
|
| 05 | 2.6218: Turn off equipment when not in use | $1,965 | - | - | - |
$1,965
-
MMBtu
|
|
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $7,694 | $1,312 |
$4,606
75,632
kWh
|
$3,088
-
kW-mo/yr
|
- | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $28,329 | $57,678 |
$17,029
279,622
kWh
|
$11,300
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $46,942 | $73,155 |
$24,990
410,342
kWh
|
$14,388
-
kW-mo/yr
|
$7,564
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $40,829 | $62,026 |
$23,840
391,458
kWh
|
$14,388
-
kW-mo/yr
|
$2,601
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs