Assessment Year | 1990 |
---|---|
Principal Product | TUBE LIGHTING |
NAICS |
n/a
|
SIC | 3641: Electric Lamp Bulbs and Tubes |
Sales Range | $1 M to 5M |
# of Employees | 75 |
Plant Area |
n/a
|
Annual Production | 5,200,000
pieces
|
Production Hrs. Annual | 2,250
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $60,591 | 1,005,862 |
kWh
|
$0.060 |
Natural Gas | $7,776 | 1,711 |
MMBtu
|
$4.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,265 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,280 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,545 | - |
$1,545
23,447
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $570 | - |
$600
16,999
kWh
|
- | $(-30.0) | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $652 | $3,027 |
$588
8,792
kWh
|
- | $64 | |
04 | 2.2437: Recover waste heat from equipment | $333 | $1,280 | - |
$333
-
MMBtu
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $165 | - |
$165
2,931
kWh
|
- | - | |
TOTAL RECOMMENDED | $3,265 | $4,307 |
$2,898
52,169
kWh
|
$333
-
MMBtu
|
$34 | ||
TOTAL IMPLEMENTED | $2,280 | - |
$2,310
43,377
kWh
|
- | $(-30.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs