Assessment Year 2014
Principal Product Plastic and hazmat containers
NAICS 332431: Metal Can Manufacturing
SIC 3411: Metal Cans
Sales Range $10
M
to 50
M
# of Employees 137
Plant Area 237,206
ft2
Annual Production 41,600
ton
Production Hrs. Annual 7,488
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $112,405 4,286,978
kWh
Electricity Demand $196,046 11,307
kW-mo/yr
Natural Gas $228,928 32,040
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $52,054 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $27,337

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $18,022 $11,662 $9,139
315,020
kWh
$8,883
-
kW-mo/yr
- - -
02 2.2414: Use waste heat from hot flue gases to preheat $8,078 $11,520 $(-431.0)
(-14,864)
kWh
- - $8,509
-
MMBtu
-
03 2.7243: Improve air circulation with destratification fans / other methods $4,929 $2,475 $(-142.0)
(-4,888)
kWh
$(-141.0)
-
kW-mo/yr
- $5,212
-
MMBtu
-
04 2.2437: Recover waste heat from equipment $4,140 $2,788 - - - $4,140
-
MMBtu
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $3,543 $3,291 $1,784
61,500
kWh
$1,759
-
kW-mo/yr
- - -
06 2.4157: Establish a predictive maintenance program $2,967 $1,000 $2,175
74,961
kWh
$2,111
-
kW-mo/yr
- - $(-1,319.0)
07 2.3212: Optimize plant power factor $2,869 $13,803 - - $2,869 - -
08 2.1135: Repair furnaces and oven doors so that they seal efficiently $2,520 $894 $(-190.0)
(-6,555)
kWh
$(-193.0)
-
kW-mo/yr
- $2,903
-
MMBtu
-
09 2.6231: Utilize controls to operate equipment only when needed $2,181 $2,188 $1,108
38,183
kWh
$1,073
-
kW-mo/yr
- - -
10 2.1233: Analyze flue gas for proper air/fuel ratio $1,088 $500 - - - $1,144
-
MMBtu
$(-56.0)
11 2.4239: Eliminate or reduce compressed air usage $934 $1,078 $477
16,427
kWh
$457
-
kW-mo/yr
- - -
12 2.4151: Develop a repair/replace policy $783 $396 $515
17,754
kWh
$493
-
kW-mo/yr
- - $(-225.0)
TOTAL RECOMMENDED $52,054 $51,595 $14,435
497,538
kWh
$14,442
-
kW-mo/yr
$2,869 $21,908
-
MMBtu
$(-1,600.0)
TOTAL IMPLEMENTED $27,337 $17,927 $14,090
485,662
kWh
$13,703
-
kW-mo/yr
- $1,144
-
MMBtu
$(-1,600.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs