Assessment Year | 2010 |
---|---|
Principal Product | Window Balance Systems |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
100,000
ft2
|
Annual Production | 20,000,000
pieces
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | Maryland |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $156,442 | 1,748,670 |
kWh
|
$0.089 |
Electricity Demand | $16,974 | 6,346 |
kW-mo/yr
|
$2.67 |
Electricity Fees | $988 | - |
|
- |
LPG | $28,289 | 1,130 |
MMBtu
|
$25.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,772 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,083 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,129 | $42,755 |
$9,312
104,089
kWh
|
$817
-
kW-mo/yr
|
- | |
02 | 2.7231: Use radiant heater for spot heating | $8,114 | $4,540 | - | - |
$8,114
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,475 | $4,751 |
$2,253
25,189
kWh
|
$222
-
kW-mo/yr
|
- | |
04 | 2.7314: Reduce ventilation air | $1,892 | $1,078 | - | - |
$1,892
-
MMBtu
|
|
05 | 2.4151: Develop a repair/replace policy | $1,917 | $804 |
$1,768
19,762
kWh
|
$149
-
kW-mo/yr
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,359 | $588 |
$1,250
13,970
kWh
|
$109
-
kW-mo/yr
|
- | |
07 | 2.2628: Utilize a less expensive cooling method | $1,180 | $10,000 |
$1,038
11,601
kWh
|
$142
-
kW-mo/yr
|
- | |
08 | 2.1113: Reduce combustion air flow to optimum | $747 | $1,000 | - | - |
$747
-
MMBtu
|
|
09 | 2.4221: Install compressor air intakes in coolest locations | $398 | $342 |
$366
4,089
kWh
|
$32
-
kW-mo/yr
|
- | |
10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $367 | $27 |
$338
3,780
kWh
|
$29
-
kW-mo/yr
|
- | |
11 | 2.4235: Remove or close off unneeded compressed air lines | $194 | - |
$194
1,990
kWh
|
- | - | |
TOTAL RECOMMENDED | $28,772 | $65,885 |
$16,519
184,470
kWh
|
$1,500
-
kW-mo/yr
|
$10,753
-
MMBtu
|
||
TOTAL IMPLEMENTED | $25,083 | $54,739 |
$13,153
147,028
kWh
|
$1,177
-
kW-mo/yr
|
$10,753
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs