Assessment Year 2008
Principal Product Poultry Feed
NAICS 311119: Other Animal Food Manufacturing
SIC 2048: Prepared Feed and Feed Ingredients for Animals and Fowls, Except Dogs and Cats
Sales Range $50
M
to 100
M
# of Employees 36
Plant Area 22,000
ft2
Annual Production 416,000
ton
Production Hrs. Annual 6,864
hrs
Location (State) Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $452,545 11,126,556
kWh
Electricity Demand $160,379 25,212
kW-mo/yr
Electricity Fees $1,044 -
Natural Gas $523,823 51,814
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $36,252 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $13,919

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings
01 2.4111: Utilize energy-efficient belts and other improved mechanisms $13,545 $1,000 $11,259
276,834
kWh
$3,078
-
kW-mo/yr
- $(-792.0) -
02 2.4151: Develop a repair/replace policy $10,724 $1,094 $8,530
209,730
kWh
$2,344
-
kW-mo/yr
- $(-150.0) -
03 2.2437: Recover waste heat from equipment $3,084 $1,070 - - $3,084
-
MMBtu
- -
04 2.2511: Insulate bare equipment $2,032 $577 - - $2,032
-
MMBtu
- -
05 2.1233: Analyze flue gas for proper air/fuel ratio $1,872 $2,000 - - $2,022
-
MMBtu
$(-150.0) -
06 2.3212: Optimize plant power factor $1,800 $11,500 - - - - $1,800
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,609 $6,026 $960
33,634
kWh
$649
-
kW-mo/yr
- - -
08 2.4239: Eliminate or reduce compressed air usage $870 $308 $387
9,527
kWh
$483
-
kW-mo/yr
- - -
09 2.4221: Install compressor air intakes in coolest locations $364 $438 $286
7,028
kWh
$78
-
kW-mo/yr
- - -
10 2.4231: Reduce the pressure of compressed air to the minimum required $352 $25 $276
6,796
kWh
$76
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $36,252 $24,038 $21,698
543,549
kWh
$6,708
-
kW-mo/yr
$7,138
-
MMBtu
$(-1,092.0) $1,800
TOTAL IMPLEMENTED $13,919 $7,891 $10,439
266,715
kWh
$3,630
-
kW-mo/yr
- $(-150.0) -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs