| Assessment Year | 2008 |
|---|---|
| Principal Product | Rebuilt aircraft engines |
| NAICS | 336412: Aircraft Engine and Engine Parts Manufacturing |
| SIC | 3724: Aircraft Engines and Engine Parts |
| Sales Range | $100 M to 500M |
| # of Employees | 525 |
| Plant Area |
184,000
ft2
|
| Annual Production | 400
pieces
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $261,863 | 10,295,194 |
kWh
|
$0.025 |
| Electricity Demand | $200,039 | 20,717 |
kW-mo/yr
|
$9.66 |
| Electricity Fees | $2,434 | - |
|
- |
| Natural Gas | $377,149 | 33,861 |
MMBtu
|
$11.14 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $79,559 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $39,741 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $28,998 | $34,945 |
$17,416
685,665
kWh
|
$11,582
-
kW-mo/yr
|
- | - | |
| 02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $13,813 | $2,000 | - | - |
$13,903
-
MMBtu
|
$(-90.0) | |
| 03 | 2.7111: Reduce illumination to minimum necessary levels | $10,188 | $511 |
$6,121
240,992
kWh
|
$4,067
-
kW-mo/yr
|
- | - | |
| 04 | 2.2437: Recover waste heat from equipment | $7,107 | $540 | - | - |
$7,107
-
MMBtu
|
- | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,593 | $8,011 |
$2,975
117,138
kWh
|
$2,618
-
kW-mo/yr
|
- | - | |
| 06 | 2.4157: Establish a predictive maintenance program | $5,074 | $4,500 |
$3,360
132,294
kWh
|
$2,234
-
kW-mo/yr
|
- | $(-520.0) | |
| 07 | 2.4151: Develop a repair/replace policy | $3,550 | $890 |
$2,240
88,198
kWh
|
$1,490
-
kW-mo/yr
|
- | $(-180.0) | |
| 08 | 2.4239: Eliminate or reduce compressed air usage | $2,560 | $2,750 |
$1,768
69,597
kWh
|
$792
-
kW-mo/yr
|
- | - | |
| 09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,523 | - |
$914
35,995
kWh
|
$609
-
kW-mo/yr
|
- | - | |
| 10 | 2.4221: Install compressor air intakes in coolest locations | $1,153 | $460 |
$798
31,400
kWh
|
$355
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $79,559 | $54,607 |
$35,592
1,401,279
kWh
|
$23,747
-
kW-mo/yr
|
$21,010
-
MMBtu
|
$(-790.0) | ||
| TOTAL IMPLEMENTED | $39,741 | $15,912 |
$15,610
614,617
kWh
|
$11,018
-
kW-mo/yr
|
$13,903
-
MMBtu
|
$(-790.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs