Assessment Year | 2007 |
---|---|
Principal Product | Printed Signs and Decals for Vending Machines |
NAICS | 323113: Commercial Screen Printing |
SIC | 3993: Signs and Advertising Specialties |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
100,000
ft2
|
Annual Production | 1,080,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $209,286 | 3,331,756 |
kWh
|
$0.063 |
Other Energy | $31,114 | 1,466 |
MMBtu
|
$21.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $90,893 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $68,770 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Other Energy Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,046 | $8,058 |
$18,046
287,269
kWh
|
- | - | - | |
02 | 2.2437: Recover waste heat from equipment | $12,878 | $8,630 | - |
$16,878
-
MMBtu
|
- | $(-4,000.0) | |
03 | 2.7232: Replace existing hvac unit with high efficiency model | $12,259 | $122,100 |
$12,259
198,138
kWh
|
- | - | - | |
04 | 2.8112: Combine utility meters | $11,248 | $12,500 | - | - | $11,248 | - | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $8,928 | $511 |
$8,928
142,114
kWh
|
- | - | - | |
06 | 2.7241: Install outside air damper / economizer on hvac unit | $8,228 | $9,945 |
$8,228
130,971
kWh
|
- | - | - | |
07 | 2.4224: Upgrade controls on compressors | $7,036 | $984 |
$7,036
112,008
kWh
|
- | - | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $5,820 | $183 |
$5,820
92,664
kWh
|
- | - | - | |
09 | 2.7261: Install timers and/or thermostats | $3,839 | $1,105 |
$187
3,040
kWh
|
$3,652
-
MMBtu
|
- | - | |
10 | 2.2711: Utilize outside air instead of conditioned air for drying | $2,611 | $4,505 | - |
$2,611
-
MMBtu
|
- | - | |
TOTAL RECOMMENDED | $90,893 | $168,521 |
$60,504
966,204
kWh
|
$23,141
-
MMBtu
|
$11,248 | $(-4,000.0) | ||
TOTAL IMPLEMENTED | $68,770 | $153,932 |
$53,281
851,156
kWh
|
$19,489
-
MMBtu
|
- | $(-4,000.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Other Energy Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs