Assessment Year 2007
Principal Product Decorative metal sheets, toys
NAICS 339930: Doll, Toy, and Game Manufacturing
SIC 3944: Games, Toys, and Children's Vehicles, Except Dolls and Bicycles
Sales Range $5
M
to 10
M
# of Employees 60
Plant Area 600,000
ft2
Annual Production 42,000,000
units
Production Hrs. Annual 4,160
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $184,725 4,844,700
kWh
Electricity Demand $288,720 14,436
kW-mo/yr
Electricity Fees $6,862 -
Natural Gas $814,023 88,042
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $153,874 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,073

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.1133: Adjust burners for efficient operation $48,535 $170,000 - - $48,535
-
MMBtu
-
02 2.5195: Change product design to reduce energy requirements $44,169 $15,000 - - $44,169
-
MMBtu
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $31,939 $70,000 $12,699
333,307
kWh
$19,240
-
kW-mo/yr
- -
04 2.2437: Recover waste heat from equipment $5,938 $700 - - $5,938
-
MMBtu
-
05 2.4151: Develop a repair/replace policy $5,516 $1,900 $2,252
59,098
kWh
$3,564
-
kW-mo/yr
- $(-300.0)
06 2.4157: Establish a predictive maintenance program $5,399 $1,000 $2,252
59,098
kWh
$3,564
-
kW-mo/yr
- $(-417.0)
07 2.4221: Install compressor air intakes in coolest locations $4,158 $400 $1,898
49,810
kWh
$2,260
-
kW-mo/yr
- -
08 2.2628: Utilize a less expensive cooling method $2,676 $3,700 $574
15,048
kWh
$2,102
-
kW-mo/yr
- -
09 2.4231: Reduce the pressure of compressed air to the minimum required $2,188 $25 $868
22,783
kWh
$1,320
-
kW-mo/yr
- -
10 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,930 $300 $770
20,203
kWh
$1,160
-
kW-mo/yr
- -
11 2.4239: Eliminate or reduce compressed air usage $1,426 $900 $706
18,533
kWh
$720
-
kW-mo/yr
- -
TOTAL RECOMMENDED $153,874 $263,925 $22,019
577,880
kWh
$33,930
-
kW-mo/yr
$98,642
-
MMBtu
$(-717.0)
TOTAL IMPLEMENTED $25,073 $8,525 $7,422
194,763
kWh
$12,430
-
kW-mo/yr
$5,938
-
MMBtu
$(-717.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings