Assessment Year | 2006 |
---|---|
Principal Product | chemicals for the oil and natural gas drilling industry |
NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 19 |
Plant Area |
100,400
ft2
|
Annual Production | 22,000,000
lb
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $89,842 | 1,283,073 |
kWh
|
$0.070 |
Natural Gas | $130,136 | 9,538 |
MMBtu
|
$13.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $35,304 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $25,380 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $12,230 | $1,143 |
$12,230
174
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,998 | $13,688 |
$9,998
142,758
kWh
|
- | - | |
03 | 2.7231: Use radiant heater for spot heating | $4,996 | $8,800 | - |
$4,996
-
MMBtu
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,442 | $4,540 |
$2,442
34,867
kWh
|
- | - | |
05 | 2.2437: Recover waste heat from equipment | $1,952 | $656 | - |
$1,952
-
MMBtu
|
- | |
06 | 2.2511: Insulate bare equipment | $1,502 | $737 | - |
$1,502
-
MMBtu
|
- | |
07 | 2.4151: Develop a repair/replace policy | $850 | $230 |
$1,498
21,389
kWh
|
- | $(-648.0) | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $800 | $14 |
$800
11,347
kWh
|
- | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $534 | $131 |
$534
7,576
kWh
|
- | - | |
TOTAL RECOMMENDED | $35,304 | $29,939 |
$27,502
218,111
kWh
|
$8,450
-
MMBtu
|
$(-648.0) | ||
TOTAL IMPLEMENTED | $25,380 | $15,812 |
$24,526
175,668
kWh
|
$1,502
-
MMBtu
|
$(-648.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs