Assessment Year | 2005 |
---|---|
Principal Product | Ground and Machined Parts |
NAICS | 331221: Rolled Steel Shape Manufacturing |
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $1 M to 5M |
# of Employees | 75 |
Plant Area |
55,000
ft2
|
Annual Production | 4,800,000
pieces
|
Production Hrs. Annual | 4,862
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $152,855 | 1,944,000 |
kWh
|
$0.079 |
Electricity Demand | $39,589 | 5,923 |
kW-mo/yr
|
$6.68 |
Electricity Fees | $1,593 | - |
|
- |
Natural Gas | $53,550 | 5,381 |
MMBtu
|
$9.95 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,688 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $12,649 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,415 | $1,613 |
$3,650
46,294
kWh
|
$765
-
kW-mo/yr
|
- | - | |
02 | 2.4325: Upgrade conveyors | $2,844 | $4,000 |
$2,350
29,959
kWh
|
$494
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,508 | $9,090 |
$2,074
26,313
kWh
|
$434
-
kW-mo/yr
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,125 | $454 |
$2,004
25,389
kWh
|
$421
-
kW-mo/yr
|
- | $(-300.0) | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,363 | $25 |
$1,129
14,258
kWh
|
$234
-
kW-mo/yr
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,363 | $2,650 |
$1,129
14,258
kWh
|
$234
-
kW-mo/yr
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,340 | $210 |
$1,106
14,139
kWh
|
$234
-
kW-mo/yr
|
- | - | |
08 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,323 | $1,782 | - | - |
$1,323
-
MMBtu
|
- | |
09 | 2.4151: Develop a repair/replace policy | $875 | $312 |
$1,221
15,529
kWh
|
$254
-
kW-mo/yr
|
- | $(-600.0) | |
10 | 2.4221: Install compressor air intakes in coolest locations | $532 | $140 |
$438
5,537
kWh
|
$94
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $18,688 | $20,276 |
$15,101
191,676
kWh
|
$3,164
-
kW-mo/yr
|
$1,323
-
MMBtu
|
$(-900.0) | ||
TOTAL IMPLEMENTED | $12,649 | $14,144 |
$11,207
142,041
kWh
|
$2,342
-
kW-mo/yr
|
- | $(-900.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs