*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2005
Principal Product Plastic Moldings
NAICS 326121: Unlaminated Plastics Profile Shape Manufacturing
SIC 3082: Unsupported Plastics Profile Shapes
Sales Range $5
M
to 10
M
# of Employees 47
Plant Area 106,000
ft2
Annual Production 3,000,000
lb
Production Hrs. Annual 6,120
hrs
Location (State) Ohio

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $70,454 1,433,222
kWh
Electricity Demand $41,091 4,702
kW-mo/yr
Electricity Fees $(-4,796.0) -
Natural Gas $7,199 827
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $41,117 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $26,209

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Personnel Changes Savings Water Consumption Savings
01 2.2511: Insulate bare equipment $9,618 $1,147 $6,999
152,799
kWh
$2,619
-
kW-mo/yr
- - - -
02 2.4322: Use or replace with energy efficient substitutes $3,338 $550 $2,429
53,165
kWh
$909
-
kW-mo/yr
- - - -
03 2.7111: Reduce illumination to minimum necessary levels $2,461 $760 $1,704
37,211
kWh
$757
-
kW-mo/yr
- - - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $2,239 $8,590 $1,510
32,971
kWh
$729
-
kW-mo/yr
- - - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,140 $98 $1,557
33,996
kWh
$583
-
kW-mo/yr
- - - -
06 2.2437: Recover waste heat from equipment $1,646 $232 - - $1,646
-
MMBtu
- - -
07 2.4231: Reduce the pressure of compressed air to the minimum required $1,551 $19 $1,129
24,632
kWh
$422
-
kW-mo/yr
- - - -
08 2.7135: Install occupancy sensors $1,334 $1,436 $962
21,000
kWh
$372
-
kW-mo/yr
- - - -
09 2.7124: Make a practice of turning off lights when not needed $1,138 - $588
12,837
kWh
$550
-
kW-mo/yr
- - - -
10 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,066 $507 $778
16,994
kWh
$288
-
kW-mo/yr
- - - -
11 2.4151: Develop a repair/replace policy $1,012 $133 $1,066
23,440
kWh
$402
-
kW-mo/yr
- - $(-456.0) -
12 2.4221: Install compressor air intakes in coolest locations $512 $480 $373
8,124
kWh
$139
-
kW-mo/yr
- - - -
13 2.7142: Utilize higher efficiency lamps and/or ballasts $374 - $272
5,924
kWh
$102
-
kW-mo/yr
- - - -
14 3.4115: Recover and reuse cooling water $12,688 $5,135 $(-1,007.0)
(-21,975)
kWh
$(-375.0)
-
kW-mo/yr
- $8,819
-
Tgal
- $5,251
-
Tgal
TOTAL RECOMMENDED $41,117 $19,087 $18,360
401,118
kWh
$7,497
-
kW-mo/yr
$1,646
-
MMBtu
$8,819
-
Tgal
$(-456.0) $5,251
-
Tgal
TOTAL IMPLEMENTED $26,209 $12,036 $17,760
388,045
kWh
$7,259
-
kW-mo/yr
$1,646
-
MMBtu
- $(-456.0) -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Water Disposal Savings Personnel Changes Savings Water Consumption Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs