| Assessment Year | 1995 |
|---|---|
| Principal Product | Sheet Metal Products |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 65 |
| Plant Area |
89,000
ft2
|
| Annual Production | 4,100
ton
|
| Production Hrs. Annual | 4,808
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $48,317 | 650,938 |
kWh
|
$0.074 |
| Natural Gas | $20,010 | 4,258 |
MMBtu
|
$4.70 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,122 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $239 | $1,130 |
$239
3,224
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,964 | $16,588 |
$11,964
161,196
kWh
|
- | |
| 03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $101 | $300 | - |
$101
-
MMBtu
|
|
| 04 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $202 | $887 |
$202
10,844
kWh
|
- | |
| 05 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $616 | $2,420 |
$616
32,825
kWh
|
- | |
| TOTAL RECOMMENDED | $13,122 | $21,325 |
$13,021
208,089
kWh
|
$101
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs