Assessment Year | 1995 |
---|---|
Principal Product | Sheet Metal Products |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
89,000
ft2
|
Annual Production | 4,100
ton
|
Production Hrs. Annual | 4,808
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $48,317 | 650,938 |
kWh
|
$0.074 |
Natural Gas | $20,010 | 4,258 |
MMBtu
|
$4.70 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,122 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $239 | $1,130 |
$239
3,224
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,964 | $16,588 |
$11,964
161,196
kWh
|
- | |
03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $101 | $300 | - |
$101
-
MMBtu
|
|
04 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $202 | $887 |
$202
10,844
kWh
|
- | |
05 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $616 | $2,420 |
$616
32,825
kWh
|
- | |
TOTAL RECOMMENDED | $13,122 | $21,325 |
$13,021
208,089
kWh
|
$101
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs