| Assessment Year | 2001 |
|---|---|
| Principal Product | Compact Construction Equipment |
| NAICS |
n/a
|
| SIC | 3531: Construction Machinery and Equipment |
| Sales Range | $1 M to 5M |
| # of Employees | 130 |
| Plant Area |
100,000
ft2
|
| Annual Production | 675
pieces
|
| Production Hrs. Annual | 4,080
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $84,498 | 1,204,549 |
kWh
|
$0.070 |
| Natural Gas | $5,118 | 761 |
MMBtu
|
$6.73 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $69,833 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,023 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $370 | $120 |
$370
5,274
kWh
|
- | - | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $642 | $40 |
$642
9,083
kWh
|
- | - | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $637 | $450 |
$637
9,962
kWh
|
- | - | - | |
| 04 | 2.2437: Recover waste heat from equipment | $1,550 | $160 | - |
$1,550
-
MMBtu
|
- | - | |
| 05 | 2.4157: Establish a predictive maintenance program | $3,626 | $1,600 |
$3,626
51,568
kWh
|
- | - | - | |
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $2,746 | $480 |
$2,746
39,262
kWh
|
- | - | - | |
| 07 | 2.7144: Install spectral reflectors / delamp | $822 | $1,575 |
$822
11,720
kWh
|
- | - | - | |
| 08 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $19,440 | $6,080 | - | - |
$19,440
-
gal
|
- | |
| 09 | 4.652: Replace existing equipment with more suitable substitutes | $20,000 | $7,000 | - | - | - | $20,000 | |
| 10 | 4.652: Replace existing equipment with more suitable substitutes | $20,000 | $12,000 | - | - | - | $20,000 | |
| TOTAL RECOMMENDED | $69,833 | $29,505 |
$8,843
126,869
kWh
|
$1,550
-
MMBtu
|
$19,440
-
gal
|
$40,000 | ||
| TOTAL IMPLEMENTED | $10,023 | $4,305 |
$8,473
121,595
kWh
|
$1,550
-
MMBtu
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Liquid (haz) Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs