Assessment Year 2000
Principal Product Deep drawn metal containers
NAICS
n/a
SIC 3411: Metal Cans
Sales Range $10
M
to 50
M
# of Employees 133
Plant Area 92,000
ft2
Annual Production 66,500,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $222,793 3,966,002
kWh
Electricity Demand $110,911 11,083
kW-mo/yr
Natural Gas $51,923 6,076
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $171,760 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $26,142

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Solid Waste (haz) Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.2437: Recover waste heat from equipment $11,419 $800 - - $11,419
-
MMBtu
- - - -
02 2.4221: Install compressor air intakes in coolest locations $3,709 $800 $2,215
78,546
kWh
$1,494
-
kW-mo/yr
- - - - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $347 $519 $307
2,931
kWh
$40
-
kW-mo/yr
- - - - -
04 2.2622: Replace existing chiller with high efficiency model $7,568 $3,000 $4,519
160,023
kWh
$3,049
-
kW-mo/yr
- - - - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $394 $50 $281
5,862
kWh
$113
-
kW-mo/yr
- - - - -
06 2.7144: Install spectral reflectors / delamp $7,688 $7,933 $4,597
162,368
kWh
$3,091
-
kW-mo/yr
- - - - -
07 2.7111: Reduce illumination to minimum necessary levels $6,511 $600 $3,887
137,749
kWh
$2,624
-
kW-mo/yr
- - - - -
08 2.7243: Improve air circulation with destratification fans / other methods $6,109 $1,500 - - $6,109
-
MMBtu
- - - -
09 2.2515: Use optimum thickness insulation $171 $375 - - $171
-
MMBtu
- - - -
10 2.4157: Establish a predictive maintenance program $9,414 $1,000 $5,621
199,297
kWh
$3,793
-
kW-mo/yr
- - - - -
11 3.5316: Contract a wood pallet recycling company $480 $100 - - - $480
-
lb
- - -
12 3.5212: Regrind, reuse, or sell scrap plastic parts $80 - - - - - $80
-
lb
- -
13 3.6193: Install equipment (eg compactor) to reduce disposal costs $5,182 $7,000 - - - $5,182
-
lb
- - -
14 4.445: Install equipment to move product $77,688 $750 - - - - - $77,688 -
15 4.611: Begin a practice of predictive / preventative maintenance $35,000 $5,000 - - - - - - $35,000
TOTAL RECOMMENDED $171,760 $29,427 $21,427
746,776
kWh
$14,204
-
kW-mo/yr
$17,699
-
MMBtu
$5,662
-
lb
$80
-
lb
$77,688 $35,000
TOTAL IMPLEMENTED $26,142 $12,977 $15,325
530,481
kWh
$10,086
-
kW-mo/yr
$171
-
MMBtu
$480
-
lb
$80
-
lb
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Solid Waste (haz) Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs