Assessment Year 2000
Principal Product Business Forms
NAICS
n/a
SIC 2671: Packaging Paper and Plastics Film, Coated and Laminated
Sales Range $10
M
to 50
M
# of Employees 135
Plant Area 88,595
ft2
Annual Production 7,000,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $100,162 2,657,679
kWh
Electricity Demand $37,381 7,388
kW-mo/yr
Electricity Fees $6,237 -
Natural Gas $16,508 2,030
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $47,064 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $22,719

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Solid Waste (non-haz) Savings Solid Waste (haz) Savings Primary Product Savings
01 2.2437: Recover waste heat from equipment $2,260 $900 - $2,260
-
MMBtu
- - -
02 2.4157: Establish a predictive maintenance program $2,476 $602 $2,476
49,824
kWh
- - - -
03 2.7144: Install spectral reflectors / delamp $10,427 $7,112 $10,427
209,555
kWh
- - - -
04 2.7135: Install occupancy sensors $375 $200 $375
9,379
kWh
- - - -
05 2.4322: Use or replace with energy efficient substitutes $868 $575 $868
21,688
kWh
- - - -
06 2.4221: Install compressor air intakes in coolest locations $727 $188 $727
18,171
kWh
- - - -
07 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,659 $1,040 $1,659
41,325
kWh
- - - -
08 2.4231: Reduce the pressure of compressed air to the minimum required $927 $30 $927
23,154
kWh
- - - -
09 3.5316: Contract a wood pallet recycling company $300 $100 - - $300
-
lb
- -
10 3.5217: Reuse / recycle/ sell paper products $6,930 $920 - - $6,930
-
lb
- -
11 3.5212: Regrind, reuse, or sell scrap plastic parts $115 $45 - - - $115
-
lb
-
12 4.652: Replace existing equipment with more suitable substitutes $20,000 $3,500 - - - - $20,000
TOTAL RECOMMENDED $47,064 $15,212 $17,459
373,096
kWh
$2,260
-
MMBtu
$7,230
-
lb
$115
-
lb
$20,000
TOTAL IMPLEMENTED $22,719 $9,804 $15,489
323,858
kWh
- $7,230
-
lb
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Solid Waste (non-haz) Savings Solid Waste (haz) Savings Primary Product Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs